E Initialize failed, 000F SMART threshold exceeded
UPC - 693494970128
View all 3Ware 9550SXU-12 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 282 highlights
Troubleshooting Action Allow the initialization to complete. This will return the unit to its normal redundant state. See Also For more information, see "About Initialization" on page 158 000E Initialize failed Event Type Error Cause The 3ware RAID controller was unable to complete the initialization. This error can be caused by unrecoverable drive errors. If this unit was a redundant unit, and the initialization failed because of a problem on a particular disk drive, then the unit will be degraded. Action If the unit was degraded, then rebuild the unit. This may necessitate replacing the drive. Check physical cable and power connections. You can also run the drive manufacturer's diagnostic and repair utilities on the drive. See Also For links to drive manufacturer diagnostic utilities and troubleshooting advice, see http://www.3ware.com/KB/article.aspx?id=10894. "Basic Troubleshooting: Check This First" on page 251 000F SMART threshold exceeded Event Type Warning Cause SMART monitoring is predicting a potential drive failure. The 3ware RAID controller supports SMART monitoring, whereby the individual drives automatically monitor certain parametric information such 270 3ware SAS/SATA RAID Software User Guide, Version 9.5.1