3Ware 9550SXU-12 User Guide - Page 300
F Flash file system error detected, Flash file system repaired, Event Type, Cause, Action
UPC - 693494970128
View all 3Ware 9550SXU-12 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 300 highlights
Troubleshooting "Scheduling Background Tasks" on page 173 003F Flash file system error detected Event Type Warning Cause A corrupted flash file system was found on the 3ware RAID controller during boot-up. The 3ware RAID controller stores configuration parameters as files in its flash memory. These files can be corrupted when a flash operation is interrupted by events such as a power failure. The controller will attempt to restore the flash files from a backup copy. Action Update to the latest firmware, as earlier firmware resets corrupted files to default settings. We recommend using 3DM, CLI or 3BM to check your settings, in case they were not able to be restored. 0040 Flash file system repaired Event Type Information Cause A corrupted flash file system has been successfully repaired. Some of the flash files with insufficient data may have been lost in the operation. The configuration parameters which are lost will then return to their default values. Action We recommend using 3DM, CLI or 3BM to check your settings, in case they were not able to be restored. 288 3ware SAS/SATA RAID Software User Guide, Version 9.5.1