3Ware 9550SXU-12 User Guide - Page 317
Enclosure temp above operating, Enclosure temp removed
UPC - 693494970128
View all 3Ware 9550SXU-12 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 317 highlights
Error and Notification Messages Cause Applies only to the 9690SA controller. The enclosure temperature is below the enclosure manufacturer's specified operating temperature. Action In general, cooler operating temperatures are good for enclosure components. However, if the temperature is very cold, condensation can occur and cause media errors and damage. Take steps to bring the operating environment back within the enclosure manufacturer's specifications. Allow cold equipment to warm up gradually before powering on. 8024 Enclosure temp above operating Event Type Error. Cause Applies only to the 9690SA controller. The enclosure temperature is above the enclosure manufacturer's specified operating temperature. Action Make sure that the fans are operational. Check for blocked ventilation in the enclosure and the operating environment. Continued operation of the enclosure at high temperatures may lead to data loss and operational failure. 8025 Enclosure temp removed Event Type Warning. Cause Applies only to the 9690SA controller. The temperature sensor in the enclosure has been removed or has failed and the enclosure temperature is no longer being monitored. www.3ware.com 305