Adaptec 2410SA User Guide - Page 121

device_ID}, partition_size={integer}] [/raid5

Page 121 highlights

Command Line Interface (CLI) container reconfigure [/stripe_size={integer}] [/mirror={boolean}] [/partition_move={boolean}] [/partition_size={integer}] [/raid5={boolean}] [/raid10={boolean}] [/restart={boolean}] [/stripe={boolean}] [/volume={boolean}] [/wait={boolean}] {container} [{device_ID}...] Changes the configuration of an array. Parameters {container}-ID number of the array to reconfigure. {device_ID}-One or more devices. Switches /stripe_size-Stripe size of the array. /mirror-Reconfigure the array as a RAID 1. /partition_move-Specifies that the array will move partitions instead of add extra space. /partition_size-Size of a partition. /raid5-Reconfigure the array as a RAID 5. /raid10-Reconfigure the array as a RAID 10 (stripe of mirrors). /restart-Restart reconfiguring the array. /stripe-Reconfigure the array as a RAID 1. /volume-Reconfigure the array as a volume. /wait- If FALSE (the default), the operation is performed in the background and the command prompt is returned immediately. If TRUE, the operation is performed immediately and the command prompt is returned only when done. container remove failover {container} {device_ID} [{device_ID}...] Removes one or more failover disks. Parameters {container}-ID of the array whose assigned failover disk is to be removed. {device_ID}-ID for the device to remove as a failover disks. C-22

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153

C-22
Command Line Interface (CLI)
container reconfigure [/stripe_size={integer}]
[/mirror={
boolean
}] [/partition_move={
boolean
}]
[/partition_size={integer}] [/raid5={
boolean
}]
[/raid10={
boolean
}] [/restart={
boolean
}]
[/stripe={
boolean
}] [/volume={
boolean
}]
[/wait={
boolean
}] {container} [{device_ID}...]
Changes the configuration of an array.
Parameters
{container}
ID number of the array to reconfigure.
{device_ID}
One or more devices.
Switches
/stripe_size
Stripe size of the array.
/mirror
Reconfigure the array as a RAID 1.
/partition_move
Specifies that the array will move partitions
instead of add extra space.
/partition_size
Size of a partition.
/raid5
Reconfigure the array as a RAID 5.
/raid10
Reconfigure the array as a RAID 10 (stripe of
mirrors).
/restart
Restart reconfiguring the array.
/stripe
Reconfigure the array as a RAID 1.
/volume
Reconfigure the array as a volume.
/wait
If
FALSE
(the default), the operation is performed in the
background and the command prompt is returned immediately.
If
TRUE
, the operation is performed immediately and the
command prompt is returned only when done.
container remove failover {container} {device_ID}
[{device_ID}...]
Removes one or more failover disks.
Parameters
{container}
ID of the array whose assigned failover disk is to
be removed.
{device_ID}
ID for the device to remove as a failover disks.