Adaptec 2410SA User Guide - Page 93
Method Keyword, ReadCache Keyword, Build, Clear, Quick Init - impacted array
UPC - 760884142103
View all Adaptec 2410SA manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 93 highlights
DOS Utilities Examples InitializeAll=Yes InitializeAll=No Method Keyword Method is an optional keyword, indicating which method to use when creating a RAID 5 array. Possible values are: I Build (the default)-Build/verify the array. I Clear-Clear the array. I Quick Init - Make the array available immediately Overall, the Build method takes longer than Clear, but it enables you to begin using the array immediately. Although faster, Clear must complete before you can begin using the array. Quick Init makes the array available immediately, but for RAID 5 write performance is impacted until a Verify with Fix is run on the array. Note: The Method property applies only to redundant arrays (RAID 1, 5, and 10). Examples Method=Build WaitForClear=No ReadCache Keyword The ReadCache keyword indicates whether the array uses read caching. Possible values are: I Yes (the default)-Enable read caching. I No-Disable read caching. The default is Yes. Example ReadCache=Yes B-29