Brother International LK3-B432E MKII Instruction Manual - English - Page 55
These values are incremented using the P2 switch, and decremented using the P4 switch.
View all Brother International LK3-B432E MKII manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 55 highlights
13. CHANGING SPECIAL FUNCTIONS USING THE MEMORY SWITCHES s Memory switches 10 - 1F Switch memo-10 memo-11 - memo-13 memo-14 memo-15 memo-16 memo-17 memo-18 memo-19 memo-1A Motion when set to ON The optional emergency stop switch can be used. - Solenoid wiper can be used (available as an option). - Needle cooler output is enabled. (Needle cooler is available by special order.) Thread take-up device is not operated at the sewing end. Thread take-up device operates one stitch before the sewing end. Presser position errors are not detected. Needle up stop position errors are not detected. memo-1b Presser can be moved up and down before the home position is detected. (Normally the presser cannot be moved up and down until after the home position has been detected.) memo-1c memo-1d memo-1E - - Errors can be reset using the EMERGENCY STOP switch. (EMERGENCY STOP switch is available as an option.) memo-1F Thread is not trimmed when an emergency stop occurs during sewing. (EMERGENCY STOP switch is available as an option.) s Memory switches 20 - 2F Switch memo-20 memo-21 memo-22 Motion when set to ON Machine head from previous B430E series is used. (Only the operation panel and box are Mark II.) Rotating-type thread breakage detector operates. (Device is available by special order.) During thread breakage detection, sensitivity is decreased from 8 to 14 stitches at the sewing start. (Sensitivity during sewing is three stitches.) memo-23 memo-24 - memo-2F When DIP switch A-8 is simultaneously ON, setting values changed using the operation panel are ignored. - s Memory switches 30 - 4F 30 to 4F are set by entering two-digit values. These values are incremented using the P2 switch, and decremented using the P4 switch. Switch memo-30 memo-31 memo-32 memo-33 memo-34 memo-35 memo-36 memo-37 memo-38 memo-39 memo-3A memo-3b memo-3c memo-3d memo-3E memo-3F Possible setting range 0 - 30 0 - 30 /zx :12 - 27 c :12 - 25 1 - 10 0 - 5 3 - 9 - 1 - 20 1 - 20 1 - 20 1 - 20 1 - 20 - - - - Units mm mm × 100rpm × 100rpm × 7.5° Needle × 100rpm - × 7.5° × 7.5° × 7.5° × 7.5° × 7.5° - - - - Initial value Explanation /zc:30 x :12 Limits the maximum area in the horizontal direction (X) /z:10 x:3,c:30 Limits the maximum area in the vertical direction (Y) 27 Changes the maximum sewing speed. 25 5 Changes the feed timing 1 (Fast) ←5 (Standard) →10 (Slow) 0 The sewing speed at the sewing start is 400 rpm for the specified number of stiches. 4 Changes the sewing start speed specified by memo-34. - - 10 Changes the feed timing one stitch before the sewing end. 1 (Fast) ←10 (Standard)→20 (Slow) 10 Changes the feed timing two stitches before the sewing end.ɹɹɹɹɹ 10 Changes the feed timing for the third stitch at the sewing start. 1 (Fast) ←10 (Standard) →20 (Slow) 10 Changes the feed timing for the second stitch at the sewing start. 10 Changes the feed timing for the first stitch at the sewing start. - - - - - - - - memo-40 - - memo-4F - - - NOTE:/...B430E Mark II, z...B431E Mark II, x...B432E Mark II, c...B433E Mark II 49 LK3-B430E-, B431E-, B432E-, B433E- Mark II