Brother International LK3-B432E MKII Instruction Manual - English - Page 58

Table Of Error Codes

Page 58 highlights

14. TABLE OF ERROR CODES 14. TABLE OF ERROR CODES DANGER Wait at least 5 minutes after turning off the power switch and disconnecting the power cord from the wall outlet before opening the face plate of the control box. Touching areas where high voltages are present can result in severe injury. If a malfunction should occur with the sewing machine, a buzzer will sound and an error code will appear in the display window. Follow the remedy procedure to eliminate the cause of the problem. Code E-13 E-20 E-21 Cause Machine specification select connector is not connected properly. Problem with machine motor stopping, or synchronizer connection error. Machine motor operation error. Remedy Turn off the power and check if connectors P3 is disconnected. Turn off the power, and then turn the machine pulley to check if the machine has locked up. Check the synchronizer connection. Check if connectors P11, P12 and P13 are disconnected. Turn off the power and check the ground wire connection. E-30 E-31 Data is outside possible sewing area due to enlargement ratio setting. Stitch pattern data overlaps the sewing area when area limiting is active. Press the RESET switch, and then set the enlargement ratio again. Press the RESET switch, and then reset the memory switches "30" and "31" or enlargement ratio. E-32 The data format of the user program (% or After changing the setting of DIP switch A-6, clear mm) does not match the setting of DIP all memory settings. (Refer to "10-16. Clearing all switch A-6. memory settings".) E-40 Length of a stitch exceeds 10 mm. E-41 Abnormality in the sewing data. E-42 Invalid program number specified. Press the RESET switch, and then set the enlargement ratio again. If programming a new sewing data, repeat the procedure from the beginning. Press the RESET switch and specify a correct number. E-50 Needle bar does not stop when the needle is raised. E-60 E-61 E-62 E-63 E-64 * Presser has not been lowered. Presser cannot be raised. Presser is not raised. Presser cannot be lowered. Work clamp does not close. E-70 Cooling fan does not operate. E-80 E-81 E-82 Motor PROM is not correctly inserted. Foot switch was depressed when the power was turned on. An operation panel switch was depressed when the power was turned on. Turn the pulley to align the index mark with the needle up stop position. (Refer to "10-12. Adjusting the needle up stop position".) Check the V-belt tension. (Refer to "3-14. Installing the V-belt".) Refer to "16. Troubleshooting". Turn off the power and check the connection of presser sensor connector P1. Turn off the power, and then check if the cooling fan is blocked with scraps of thread. Turn off the power and check. Turn off the power and check. Turn off the power and check the operation panel. Check that all panel cords are normal. E-90 Abnormal drop in power supply voltage, or power was turned on again immediately after it was turned off. Turn off the power and check the input voltage. After turning off the power, wait 3 seconds or more before turning it on again. (Refer to "10-15. Checking the input voltage".) E-91 Abnormal rise in power supply voltage. *B432E Mark II only Turn off the power and check the input voltage. (Refer to "10-15. Checking the input voltage".) LK3-B430E-, B431E-, B432E-, B433E- Mark II 52

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73

52
LK3-B430E-, B431E-, B432E-, B433E- Mark II
Wait at least 5 minutes after turning off the power switch and disconnecting the power cord from
the wall outlet before opening the face plate of the control box. Touching areas where high volt-
ages are present can result in severe injury.
Machine motor operation error.
E-13
E-20
E-21
E-30
E-32
E-31
E-40
E-41
E-42
E-50
E-60
E-61
E-62
E-64
Work clamp does not close.
E-63
E-70
E-80
E-81
E-82
E-90
E-91
Cause
Machine specification select connector is
not connected properly.
Problem with machine motor stopping, or
synchronizer connection error.
Data is outside possible sewing area due
to enlargement ratio setting.
The data format of the user program (% or
mm) does not match the setting of DIP
switch A-6.
After changing the setting of DIP switch A-6, clear
all memory settings. (Refer to
10-16. Clearing all
memory settings
.)
Stitch pattern data overlaps the sewing
area when area limiting is active.
Length of a stitch exceeds 10 mm.
Abnormality in the sewing data.
Invalid program number specified.
Needle bar does not stop when the needle
is raised.
Presser has not been lowered.
Presser cannot be raised.
Presser is not raised.
Presser cannot be lowered.
Cooling fan does not operate.
Motor PROM is not correctly inserted.
Foot switch was depressed when the
power was turned on.
An operation panel switch was depressed
when the power was turned on.
Abnormal drop in power supply voltage,
or power was turned on again
immediately after it was turned off.
Abnormal rise in power supply voltage.
Remedy
Turn off the power and check if connectors P3 is
disconnected.
Turn off the power, and then turn the machine
pulley to check if the machine has locked up. Check
the synchronizer connection. Check if connectors
P11, P12 and P13 are disconnected.
Turn off the power and check the ground wire
connection.
Press the RESET switch, and then set the
enlargement ratio again.
Press the RESET switch, and then reset the memory
switches
30
and
31
or enlargement ratio.
Press the RESET switch, and then set the
enlargement ratio again.
If programming a new sewing data, repeat the
procedure from the beginning.
Press the RESET switch and specify a correct
number.
Turn the pulley to align the index mark with the
needle up stop position. (Refer to
10-12. Adjusting
the needle up stop position
.) Check the V-belt
tension. (Refer to
3-14. Installing the V-belt
.)
Refer to
16. Troubleshooting
.
Turn off the power and check the connection of
presser sensor connector P1.
Turn off the power, and then check if the cooling
fan is blocked with scraps of thread.
Turn off the power and check.
Turn off the power and check.
Turn off the power and check the operation panel.
Check that all panel cords are normal.
Turn off the power and check the input voltage.
After turning off the power, wait 3 seconds or more
before turning it on again. (Refer to
10-15.
Checking the input voltage
.)
Turn off the power and check the input voltage.
(Refer to
10-15. Checking the input voltage
.)
Code
*
14. TABLE OF ERROR CODES
DANGER
If a malfunction should occur with the sewing machine, a buzzer will sound and an error code will appear in
the display window. Follow the remedy procedure to eliminate the cause of the problem.
14. TABLE OF ERROR CODES
*B432E Mark II only