Brother International MD-817 Service Manual - Page 21
Brush, replacement, Checking, voltage, output
View all Brother International MD-817 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 21 highlights
11 Brush replacement Val 0 1. Be sure to turn off the power switch. 2. Disconnect the motor plug. 3. Remove the clamp screws 0. 4. Remove the brushes 0. 5. After checking the reference line of the brush a mount the usable brush 0 so that the reference line points toward the treadle unit. Replace the brushes if used up to the reference a line with new ones. 6. Tighten the clamp screws 0 to a torque of 10 - 15kg-cm. 7. Connect the motor plug. Checking AC low voltage output te a; rAi•• lac•••• * The AC low voltage output cord 0 is provided at the rear of the control box. Getting power for the lamp from the AC low voltage output cord is prohibited by law in some places. a IIIII ra, 0 la r Primary side Lamp tap _J Secondary side AC low voltage output Black cord 6V 20W Gray cord 12V 20W The transformer insulates the AC low voltage output from the primary side. CAUTION: Be sure to wrap the end of the cord with tape after disconnecting the AC low voltage output cord. - 17 -