Explanation DIP switch DIPC & DIPD of NBN DIPC 1 ON OFF *1 ON *1 OFF *1 ON *1 Tension re lease OFF OFF setting at the 0 10 20 30 start of sewing ON 2 - OFF OFF ON ON OFF 3 Condense mode ON Condense mode (sett ing by needle number) OFF none 4 Slowdown control ON Normal ly slowdown (usual slowdown) OFF Fix time of inching period on slowdown Continuous backta- ON 5 ck sel ection OFF A, B sewn repeatedly D times A.B.C.D ABCD+10 cont inuous ON 6 backtack OFF 10 stitches added to the display A,B,C,D Seam A, B, C, D sewn as displayed Start condense 7 se lect ion ON Stops when treadle is returned to neutral posi tion OFF Sews to end of condensation when tread le is in ne- utral posi t ion Condense se lect 8 at correction by actuator switch ON Condense by actuator OFF none DIPD 1 Mode select ion ON Parameter setting mode OFF Normal ly sewing mode 2 Reserved Normal ly OFF 3 Reserved Normal ly OFF 4 Reserved Normal ly OFF 5 Reserved Normal ly OFF Sewing d irect ion ON 6 at finished and s- topped start B.T. OFF Stopped as reverse direct ion at f inished B Stopped as normaly direction at f inished B B+1 start B.T. or ON 1 stitch added to the displayed B seam length 7 cont inuous B. T. OFF Seam B sewn as displayed 8 D+1 end backtack ON 1 stitch added to the displayed D seam length OFF Seam D sewn as displayed *1 :The described number is the pulse from the first need le down position after thread trimming. (24pulse/round) -22-

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112

Explanation
DIP
switch
DIPC
&
DIPD
of
NBN
DIPC
1
Tension
re
lease
OFF
setting
at
the
start
of
sewing
ON
OFF
OFF
*1
0
ON
*1
10
OFF
*1
20
ON
*1
30
2
ON
-
OFF
OFF
OFF
ON
ON
3
Condense
mode
ON
Condense
mode
(sett
ing
by
needle
number)
OFF
none
4
Slowdown
control
ON
Normal
ly
slowdown
(usual
slowdown)
OFF
Fix
time
of
inching
period
on
slowdown
5
Continuous
backta—
ck
sel
ection
ON
A,
B
sewn
repeatedly
D
times
OFF
A.B.C.D
6
ABCD+10
cont
inuous
backtack
ON
10
stitches
added
to
the
display
A,B,C,D
OFF
Seam
A,
B,
C,
D
sewn
as
displayed
7
Start
condense
se
lect
ion
ON
Stops
when
treadle
is
returned
to
neutral
posi
tion
OFF
Sews
to
end
of
condensation
when
tread
le
is
in
ne—
utral
posi
t
ion
8
Condense
se
lect
at
correction
by
actuator
switch
ON
Condense
by
actuator
OFF
none
DIPD
1
Mode
select
ion
ON
Parameter
setting
mode
OFF
Normal
ly
sewing
mode
2
Reserved
Normal
ly
OFF
3
Reserved
Normal
ly
OFF
4
Reserved
Normal
ly
OFF
5
Reserved
Normal
ly
OFF
6
Sewing
d
irect
ion
at
finished
and
s—
topped
start
B.T.
ON
Stopped
as
reverse
direct
ion
at
f
inished
B
OFF
Stopped
as
normaly
direction
at
f
inished
B
7
B+1
start
B.T.
or
cont
inuous
B.
T.
ON
1
stitch
added
to
the
displayed
B
seam
length
OFF
Seam
B
sewn
as
displayed
8
D+1
end
backtack
ON
1
stitch
added
to
the
displayed
D
seam
length
OFF
Seam
D
sewn
as
displayed
*1
:The
described
number
is
the
pulse
from
the
first
need
le
down
position
after
thread
trimming.
(24pulse/round)