Canon MultiPASS C755 Service Manual - Page 103

How to Read Bit Switch Tables, Bit Switch Display, Not Output

Page 103 highlights

MultiPASS C755 Chapter 3: Maintenance & Service 6.2.4 Explanation of service data a) SSSW (Service Soft Switch settings) The items registered and set by each of these switches comprise 8-bit switches. The figure below shows which numbers are assigned to which bits. Each bit has a value of either 0 or 1. Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0 SW01 0 0 0 0 0 0 0 0 Figure 3-24 Bit Switch Display See the chart in the service data shown in this Chapter, 6.2.3 Service data setting to see effective bits and their default values. The meanings (functions) of the bits are not described in this manual except the new switches added to this model. See the G3 Facsimile Service Data Handbook (supplied separately) for details of the switches. Below are examples showing how to read bit switch tables. Indicates that the setting is "1". Indicates that the setting is "0". Figures in boldface are default settings. Bit Function 1 0 0 Service error code Output Not Output 1 Error dump list Output Not Output 2 Not used 3 Copy function No Yes 4 ##300 series service error code Output Not Output 5 Not used 6 Not used 7 User setting restriction Setting possible Setting restricted Figure 3-25 How to Read Bit Switch Tables 3-52

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143

3-52
MultiPASS C755
Chapter 3: Maintenance & Service
6.2.4 Explanation of service data
a) SSSW (Service Soft Switch settings)
The items registered and set by each of these switches comprise 8-bit switches. The figure below shows
which numbers are assigned to which bits. Each bit has a value of either 0 or 1.
See the chart in the service data shown in
this Chapter, 6.2.3 Service data setting
to see effective
bits and their default values.
The meanings (functions) of the bits are not described in this manual
except the new switches added to this model.
See
the G3 Facsimile Service Data Handbook
(supplied separately)
for details of the switches.
Below are examples showing how to read bit switch tables.
SW01
0
0
0
0
0
0
0
0
Bit 7
Bit 6
Bit 5
Bit 4
Bit 3
Bit 2
Bit 1
Bit 0
Service error code
Error dump list
Not used
Copy function
##300 series service error code
Not used
Not used
User setting restriction
Output
Output
No
Output
Setting possible
Function
0
1
2
3
4
5
6
7
Bit
1
0
Indicates that the
setting is "1".
Figures in boldface
are default settings.
Indicates that the
setting is "0".
Not Output
Not Output
Yes
Not Output
Setting restricted
Figure 3-25 How to Read Bit Switch Tables
Figure 3-24 Bit Switch Display