Denon AVR-3312CI AVR3312CI_OwnersManual - Page 27

Calculation, Measurement 2nd - 8th, ENTER - setup

Page 27 highlights

Basic version Advanced version STEP 3 Measurement (2nd - 8th) STEP 4 Calculation Set up speakers (Audyssey® Auto Setup) • In STEP 3, you will perform measurements at multiple positions (two to eight positions) other than the main listening position. • Just one position can be measured but measuring multiple positions increases the accuracy of the correction of acoustic distortion within the listening area. 9 Move the setup microphone to position 2, use ui to select "Measure", and then press ENTER. The measurement of the second position starts. Measurements can be made in up to eight positions. 10 Repeat step 9, measuring positions 3 to 8. When measurement of position 8 is completed, a "Measurements finished." message is displayed. AUDYSSEY AUTO SETUP STEP3 Measurement (Finish) Measurements finished. 1 2 3 4 5 6 Retry Next Calculation Enter Proceed to next (Calculation) RETURN Cancel AUDYSSEY AUTO SETUP STEP3 Measurement (2nd) Please place the microphone at ear height at 2nd Iistening position. 1 2 3 4 5 6 Measure Next Calculation Enter RETURN Cancel Start measurement. Output large test tone during measuring 11 On the STEP 3 screen, use ui to select "Next → Calculation", and then press ENTER. Measuring results are analyzed, and the frequency response of each speaker in the listening room is determined. AUDYSSEY AUTO SETUP STEP4 Calculation Now calculating...Please wait. 20% 1 2 3 4 5 6 • Analysis takes several minutes to complete. The time required for this analysis depends on the number of speakers connected. The more connected speakers there are, the longer it takes to perform analysis. vSee overleaf If you want to omit measurements from the next position onward, select "Next Calculation". (Go to STEP4 Calculation ) Information 24

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157

24
STEP 4
Calculation
Set up speakers (Audyssey
®
Auto Setup)
10
Repeat step 9, measuring positions 3 to 8.
When
measurement
of
position
8
is
completed,
a
“Measurements finished.” message is displayed.
AUDYSSEY AUTO SETUP
1 2 3 4 5 6
RETURN
Next
Calculation
Retry
STEP3 Measurement (Finish)
Proceed to next (Calculation)
Enter
Cancel
Measurements finished.
11
On the
STEP 3
screen, use
ui
to select “Next →
Calculation”, and then press
ENTER
.
Measuring results are analyzed, and the frequency response of
each speaker in the listening room is determined.
AUDYSSEY AUTO SETUP
1 2 3 4 5 6
STEP4 Calculation
Now calculating...Please wait.
20%
Analysis takes several minutes to complete. The time required for
this analysis depends on the number of speakers connected.
The more connected speakers there are, the longer it takes to
perform analysis.
STEP 3
Measurement (2nd – 8th)
In STEP 3, you will perform measurements at multiple positions (two
to eight positions) other than the main listening position.
Just one position can be measured but measuring multiple positions
increases the accuracy of the correction of acoustic distortion within
the listening area.
9
Move the setup microphone to
position 2, use
ui
to select
“Measure”,
and
then
press
ENTER
.
The measurement of the second
position starts. Measurements can be
made in up to eight positions.
AUDYSSEY AUTO SETUP
1 2 3 4 5 6
RETURN
Next
Calculation
Measure
STEP3 Measurement (2nd)
Start measurement. Output large test tone during measuring
Enter
Cancel
Please place the microphone at ear
height at 2nd Iistening position.
If you want to omit measurements from the next position onward,
select “Next
Calculation”.
(Go to
STEP4
Calculation
)