Garmin Rino 520HCx Owner's Manual - Page 39

Pan Plot, Calibrating the Altimeter, To use the Pan Plot option, To manually calibrate the altimeter

Page 39 highlights

Pan Plot Use the Pan Plot option to view a single point along an elevation or pressure profile. When the pointer is stopped at a location along the profile, the page shows the elevation, time of day and date the point was created. Pan Plot Option Page To use the Pan Plot option: 1. Use the Rocker to access the option menu. 2. Select the View Points option to view the View Points page and use the Rocker to scroll the profile past the pointer in the center of the page. As the profile moves past the pointer, the status window at the top of the page changes to show the date, time, and altitude for the point indicated. Basic Operation Calibrating the Altimeter Because the Rino 530HCx relies on the barometric pressure to determine the elevation and the pressure at any given elevation can fluctuate, calibrate the altimeter to increase its accuracy. You must know the elevation (from a map point or other reliable data) or the pressure (calibrated to sea level) for your current location. To manually calibrate the altimeter: 1. Use the Rocker to access the option menu. 2. Select the Calibrate Altimeter option to open the Calibration page. 3. At the message asking "Do You Know The Correct Elevation?" select Yes to enter your elevation. When finished, select OK to return to the Altimeter page. If you don't know your current elevation, select No to move to the pressure calibration page. At the message asking, "Do You Know The Correct Pressure?" select the on-screen Yes button to enter your pressure. When finished, select OK. Rino 520HCx and 530HCx Owner's Manual 33

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74

Rino 520HCx and 530HCx Owner’s Manual
33
B
ASIC
O
PERATION
Pan Plot
Use the Pan Plot option to view a single point along
an elevation or pressure profile. When the pointer is
stopped at a location along the profile, the page shows the
elevation, time of day and date the point was created.
Pan Plot Option Page
To use the Pan Plot option:
1. Use the
Rocker
to access the option menu.
2. Select the
View Points
option to view the View
Points page and use the
Rocker
to scroll the
profile past the pointer in the center of the page.
As the profile moves past the pointer, the status
window at the top of the page changes to show the
date, time, and altitude for the point indicated.
Calibrating the Altimeter
Because the Rino 530HCx relies on the barometric
pressure to determine the elevation and the pressure at
any given elevation can fluctuate, calibrate the altimeter
to increase its accuracy. You must know the elevation
(from a map point or other reliable data) or the pressure
(calibrated to sea level) for your current location.
To manually calibrate the altimeter:
1. Use the
Rocker
to access the option menu.
2. Select the
Calibrate Altimeter
option to open the
Calibration page.
3. At the message asking “Do You Know The Correct
Elevation?” select
Yes
to enter your elevation.
When finished, select
OK
to return to the Altimeter
page. If you don’t know your current elevation,
select
No
to move to the pressure calibration page.
At the message asking, “Do You Know The Correct
Pressure?” select the on-screen
Yes
button to
enter your pressure. When finished, select
OK
.