Table F-1, POST Error Messages
UPC - 720591665913
View all HP 226593-B21 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 108 highlights
POST Error Messages Table F-1: POST Error Messages continued Message Description Meaning and Recommended Action 1714 Slot x drive array - Redundant ROM checksum error. Backup ROM has been activated automatically. Check the firmware version. 1720 Slot x drive array - S.M.A.R.T. hard drive detects imminent failure: SCSI port x: SCSI ID y The indicated drive has reported a S.M.A.R.T. predictive-failure condition. It may fail at some time in the near future. Do not replace the drive unless all other drives on the array are online. Back up data before replacing drive(s). 1721 Slot x drive array - drive parameter tracking predicts imminent failure The following device(s) should be replaced when conditions permit: Do not replace the drive unless all other drives on the array are online. Back up data before replacing drive(s). M&P predictive failure threshold has been exceeded. The indicated drive(s) may fail at some time in the near future. (a list of devices will be given here). 1723 Slot x drive array - to improve signal integrity, internal SCSI connector should be removed if external drives are attached to the same SCSI port (followed by further details). Follow the remaining instructions in the POST message. continued F-2 Compaq Smart Array 5i Plus Controller and Battery Backed Write Cache Enabler User Guide