HP 226593-B21 Smart Array 5i Plus Controller and Battery Backed Write Cache En - Page 117
Run the Array Diagnostics Utility ADU if, Slot 1 Drive Array
UPC - 720591665913
View all HP 226593-B21 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 117 highlights
POST Error Messages Table F-1: POST Error Messages continued Message Description Meaning and Recommended Action 1785 Slot 1 Drive Array not Configured (may be followed by one of the following messages): (1) No drives detected (2) Drive positions appear to have changed. Run the Array Diagnostics Utility (ADU) if previous positions are unknown, then turn system power OFF and move drives to their original positions. (3) Configuration information indicates drive positions beyond the capability of this controller. This may be due to drive movement from a controller that supports more drives than the current controller. 1. Turn off the system and check SCSI cable connections to be sure that drives are attached properly. 2. Run the Array Diagnostics Utility (ADU) if previous positions are unknown. Then power the system down and move drives to their original positions. 3. To avoid data loss, power the system down and reattach drives to the original controller. 4. To avoid data loss, reattach drives to the original controller or upgrade the controller firmware to the version on the original controller using the Options ROMPaq utility. 5. Press the F1 key to resume. (4) Configuration information indicates drives were configured on a controller with a newer firmware version. continued Compaq Smart Array 5i Plus Controller and Battery Backed Write Cache Enabler User Guide F-11