HP 226593-B21 Smart Array 5i Plus Controller and Battery Backed Write Cache En - Page 61
Running CPQONLIN, Automatic Configuration, Array Configuration Utility, Enter
UPC - 720591665913
View all HP 226593-B21 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 61 highlights
Configuring an Array Running CPQONLIN 1. Enter cpqonlin at the console prompt. 2. Use the arrow keys to highlight Array Configuration Utility, and then press the Enter key. 3. From the list of controllers that is presented, select the one that you want to configure. - If no logical drives are configured for the controller, the auto-configuration wizard screen (see Figure 7-21) is displayed. - If logical drives are present on the controller, the manual configuration screen (see Figure 7-22) is displayed. Press the F1 key for online help at any time on either screen. Automatic Configuration Figure 7-21: CPQONLIN auto-configuration wizard 1. If the proposed logical configuration shown on the wizard screen is acceptable, highlight the fault tolerance level that you want for the logical drive and press the Enter key. Otherwise, select Custom Configuration and continue the procedure as described in the "Manual Configuration" section. 2. Press the Esc key to save the changes and return to the controller selection screen. Compaq Smart Array 5i Plus Controller and Battery Backed Write Cache Enabler User Guide 7-27