POST Error Messages Table F-1: POST Error Messages continued Message Description Meaning and Recommended Action 1724 Slot x drive array - physical drive position change(s) detected - logical drive configuration has automatically been updated. Logical drive configuration has been updated automatically following physical drive position changes. Press the F1 key to resume. 1726 Slot x drive array - array accelerator memory size change detected - array accelerator configuration has automatically been updated This message is displayed if the controller is replaced with a model that has a different amount of cache memory. 1727 Slot x drive array - new logical drive(s) attachment detected (if >32 logical drives, this message will be followed by Autoconfiguration failed: too many logical drives) The controller has detected an additional array of drives that was attached when the system was powered down. The logical drive configuration information has been updated to add the new logical drives. The maximum number of logical drives supported is 32-additional drives will not be added to the configuration if this number is exceeded. Press the F1 key to resume. 1728 Slot x drive array - abnormal shutdown detected with write cache enabled. This message should never occur unless the write cache is somehow enabled on a controller that does not have batteries. No array accelerator battery backup on this model array controller. Any data that may have been in array accelerator memory has been lost. continued Compaq Smart Array 5i Plus Controller and Battery Backed Write Cache Enabler User Guide F-3

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141

POST Error Messages
Compaq Smart Array 5i Plus Controller and Battery Backed Write Cache Enabler User Guide
F-3
Table F-1:
POST Error Messages
continued
Message
Description
Meaning and Recommended Action
1724
Slot x drive array –
physical drive position
change(s) detected –
logical drive
configuration has
automatically been
updated.
Logical drive configuration has been updated
automatically following physical drive position
changes. Press the
F1
key to resume.
1726
Slot x
drive array –
array accelerator
memory size change
detected – array
accelerator
configuration has
automatically been
updated
This message is displayed if the controller is
replaced with a model that has a different amount
of cache memory.
1727
Slot x
drive array –
new logical drive(s)
attachment detected (if
>32 logical drives, this
message will be
followed by
Auto-
configuration failed:
too many logical
drives
)
The controller has detected an additional array of
drives that was attached when the system was
powered down. The logical drive configuration
information has been updated to add the new
logical drives. The maximum number of logical
drives supported is 32—additional drives will not
be added to the configuration if this number is
exceeded. Press the
F1
key to resume.
1728
Slot x drive array –
abnormal shutdown
detected with write
cache enabled.
No array accelerator
battery backup on this
model array controller.
Any data that may
have been in array
accelerator memory
has been lost.
This message should never occur unless the write
cache is somehow enabled on a controller that
does not have batteries.