HP 226593-B21 Smart Array 5i Plus Controller and Battery Backed Write Cache En - Page 128

drive mirroring, ECC error correction and checking memory

Page 128 highlights

Glossary CPQONLIN An array configuration utility for Novell NetWare that can be used while the server is online. data guarding See RAID. data striping Writing data to logical drives in interleaved chunks (by byte or by sector). This technique improves system performance. drive mirroring See RAID. ECC (error correction and checking) memory A type of memory that checks and corrects single-bit or multi-bit memory errors (depending on configuration) without causing the server to halt or corrupt data. fault tolerance The ability of a server to recover from hardware problems without interrupting server performance or corrupting data. Hardware RAID is most commonly used, but there are other types of fault tolerance-for example, controller duplexing and software-based RAID. flashing Updating the flash memory on a system. Flash memory is non-volatile memory that is used to hold control code such as BIOS information. It is also very fast because it can be rewritten block by block, rather than byte by byte. hot spare See online spare. logical drive (or logical volume) A group of physical drives, or part of a group, that behaves as one storage unit. Each constituent physical drive contributes the same storage volume to the total volume of the logical drive. Has performance advantages over individual physical drives. logical drive capacity extension See capacity extension. Compaq Smart Array 5i Plus Controller and Battery Backed Write Cache Enabler User GuideGlossary-3

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141

Glossary
Compaq Smart Array 5i Plus Controller and Battery Backed Write Cache Enabler User Guide
Glossary-3
CPQONLIN
An array configuration utility for Novell NetWare that can be used while the server is online.
data guarding
See
RAID.
data striping
Writing data to logical drives in interleaved chunks (by byte or by sector). This technique
improves system performance.
drive mirroring
See
RAID.
ECC (error correction and checking) memory
A type of memory that checks and corrects single-bit or multi-bit memory errors (depending
on configuration) without causing the server to halt or corrupt data.
fault tolerance
The ability of a server to recover from hardware problems without interrupting server
performance or corrupting data. Hardware RAID is most commonly used, but there are other
types of fault tolerance—for example, controller duplexing and software-based RAID.
flashing
Updating the flash memory on a system. Flash memory is non-volatile memory that is used to
hold control code such as BIOS information. It is also very fast because it can be rewritten
block by block, rather than byte by byte.
hot spare
See
online spare.
logical drive (
or
logical volume)
A group of physical drives, or part of a group, that behaves as one storage unit. Each
constituent physical drive contributes the same storage volume to the total volume of the
logical drive. Has performance advantages over individual physical drives.
logical drive capacity extension
See
capacity extension.