HP 226593-B21 Smart Array 5i Plus Controller and Battery Backed Write Cache En - Page 95

Table D-1, Interpreting Hard Drive Status from LED Indicator Pattern

Page 95 highlights

Hard Drive Installation and Replacement Table D-1: Interpreting Hard Drive Status from LED Indicator Pattern (1) Activity On, off, or flashing Off, on, or flashing On On (2) Online On or off On Flashing Off (3) Fault Flashing Off Off Off Meaning A predictive failure alert has been received for this drive. Replace the drive as soon as possible. OK to replace the drive online if the array is configured for fault tolerance and all other drives in the array are online. The drive is online and configured as part of an array. Do not remove the drive. Removing a drive during this process may terminate the current operation and cause data loss. The drive is rebuilding or undergoing capacity expansion. Do not remove the drive. Removing a drive during this process may cause data loss. The drive is being accessed, but (1) it is not configured as part of an array, (2) it is a replacement drive and rebuild has not yet started, or (3) it is spinning up during POST continued Compaq Smart Array 5i Plus Controller and Battery Backed Write Cache User Guide D-3

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141

Hard Drive Installation and Replacement
Compaq Smart Array 5i Plus Controller and Battery Backed Write Cache User Guide
D-3
Table D-1:
Interpreting Hard Drive Status from LED Indicator Pattern
(1) Activity
(2) Online
(3) Fault
Meaning
On, off, or
flashing
On or off
Flashing
A predictive failure alert has been received for this
drive. Replace the drive as soon as possible.
Off, on, or
flashing
On
Off
OK to replace the drive online if the array is configured
for fault tolerance and all other drives in the array are
online.
The drive is online and configured as part of an array.
On
Flashing
Off
Do not remove the drive. Removing a drive during
this process may terminate the current operation
and cause data loss.
The drive is rebuilding or undergoing capacity
expansion.
On
Off
Off
Do not remove the drive. Removing a drive during
this process may cause data loss.
The drive is being accessed, but (1) it is not configured
as part of an array, (2) it is a replacement drive and
rebuild has not yet started, or (3) it is spinning up during
POST
continued