HP 226593-B21 Smart Array 5i Plus Controller and Battery Backed Write Cache En - Page 118
Diagnostics Utility ADU for more information. If, Slot x Drive Array
UPC - 720591665913
View all HP 226593-B21 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 118 highlights
POST Error Messages Table F-1: POST Error Messages continued Message Description Meaning and Recommended Action 1786 Slot x Drive Array Recovery Needed. The following SCSI drive(s) need Automatic Data Recovery: SCSI port (y): SCSI ID (x) Press the F1 key to continue with recovery of data to drive(s). Press the F2 key to continue without recovery of data to drive(s). -or- Slot x drive array recovery needed. Automatic Data Recovery previously aborted! The following SCSI drive(s) need Automatic Data Recovery (rebuild): The message normally appears when a drive is replaced in a fault-tolerant configuration when the system is powered down. In this case, press the F1 key to start the Automatic Data Recovery. The previously aborted version of the 1786 POST message will appear if the previous rebuild attempt was aborted for any reason. Run the Array Diagnostics Utility (ADU) for more information. If the replacement drive was failed, try using another replacement drive. If rebuild was aborted due to a read error from another physical drive in the array: 1. Back up all readable data on the array. 2. Run Diagnostics Surface Analysis. 3. Restore your data. SCSI port (y): SCSI ID (x) Press the F1 key to retry Automatic Data Recovery to drive. Press the F2 key to continue without starting Automatic Data Recovery. continued F-12 Compaq Smart Array 5i Plus Controller and Battery Backed Write Cache Enabler User Guide