HP 8/20q HP StorageWorks 8/20q and SN6000 Fibre Channel Switch Event Message R - Page 17
Event ID and message, Description, Action, request that was
View all HP 8/20q manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 17 highlights
Table 4 Alarm events and recommended action (Continued) Icon Event ID and message Description Action (A1003.0037) (Merge failed, Total zone member limit would be exceeded) A fabric merge failed because the total number of zone members exceeds the zoning database limit. Remove zone members from either the local switch or the remote switch, so that the combined sum is less than member limit. (A1003.0038) (Merge failed, Total zones in zonesets limit would be exceeded.) A fabric merge failed because the total number of zones in zone sets exceeds the zoning database limit. Remove zones from either the local switch or the remote switch, so that the combined sum is less than zones in zone sets limit. (A1003.0039) (Merge failed, total zone limit would be exceeded.) A fabric merge failed because the total number of zones exceeds the zoning database limit. Remove zones from either the local switch or the remote switch so that the combined sum is less than maximum zone limit. (A1003.003A) (Zone Merge conflict for ZoneSet zone_set_name (Zone mismatch for zone= zone_name, check type or members), ISOLATING) A fabric merge failed because two zones of the same name in two zone sets of the same name have different membership. Reconcile the membership in the two zones so that they are the same. (A1003.003B) (Incomplete merge request sequence received, unable to process request.) A remote switch sent a merge Check the remote switch for request that was not configuration errors or understood. equipment malfunction. (A1003.003C) (Incompatible Zoning mode, Isolating link) The fabric contains switches Configure all switches in the with a mix of interoperability fabric to have the same value mode settings. for interoperability mode. (A1003.003E) (Security: Ports downed for INVALID_ATTACH require administrative action to be brought online.) When deactivating a security set, ports that were previously downed due to security violations remain down. Reset the ports or place the ports online. (A1003.003F) (ISL group empty and links up. Set ports offline to activate.) An attempt to activate fabric binding with an ISL group that has no members is not allowed because there are Fabric inter-switch links (ISL)s logged in to the switch. Configure all ISLs offline or add each ISL member with fabric binding information to the ISL group before activating. (A1003.0040) (Zone Member type member_type unsupported.) An invalid zone member type was discovered in a zone. Hard zone membership must be defined by domain_ID and port number. Correct the member type. HP StorageWorks 8/20q and SN6000 Fibre Channel Switch Event Message Reference Guide 17