R_A_TOV or E_D_TOV has been, recon d. E_Ports will be automatically

Page 43 highlights

Table 5 Critical event messages and descriptions (Continued) Icon Event ID and message Description (C) (8600.0017) (PortApp) (External port license count exceeded, downing external port port_number) The named external port is down because the number of licensed external ports has been exceeded. (C) (8600.0018) (PortApp) (External port license became available, re-starting downed external ports) An external port that was previously down because of insufficient port licenses is now online. (C) (8600.0019) (PortApp) (Internal port license count exceeded, downing internal port port_number) A device attempted to log in to an internal port, but a license was not available. A license upgrade may be required, or a license may be released by downing ports. (C) (8600.001A) (PortApp) (Internal port license became available, re-starting downed internal ports) A license has become available and ports that had been previously downed to due to unavailable licenses will be restarted. (C) (8600.001B) (RX Seq Error D_ID sequence_destination S_ID sequence_source SEQ_ID sequence_ID OX_ID originator_exchange RX_ID recipient_exchange CMPLT complete_status NFRAMES frame_count) An error was encountered while handling the receive sequence referenced in the log message. Contact your authorized maintenance provider. (C) (8700.0007) (EPort) (Port: port_number) (Received frame from address not in Access Control List (ACL) hard zone (src address = FC_address, dest address = FC_address)) The destination for the receive frame is in a hard zone and the source is not. The frame will not be forwarded. (C) (8700.000D) (EPort) (Port: port_number) (Resetting Inter-Switch Link (ISL), a time out value has been reconfigured.) R_A_TOV or E_D_TOV has been reconfigured. E_Ports will be automatically reset to inform the neighbor switch of the change. (C) (8700.000E) (EPort) (Port: port_number) (InteropCredit value was reconfigured, resetting port.) The InteropCredit parameter has changed. The affected port will be automatically reset. (C) (8700.000F) (EPort) (Port: port_number) (Broadcast frame received & broadcast disabled, discarding broadcast frames.) Broadcast is disabled and the switch has received a broadcast frame. Enable broadcast to receive broadcast frames. (C) (8700.0010) (EPort) (Port: port_number) (Inter-Switch Link (ISL) unstable. ISL init will be held back until ISL up time is 5 seconds) The Fabric inter-switch link (ISL) is unstable, indicating that the media module or the cable is bad. (C) (8700.0011) (Eport) (Port: port_number) (Connection failure, remote switch not compatible) The remote switch is not compatible with the local switch. The E_Port cannot exchange switch capabilities with the remote switch. (C) (8700.0012) (Eport) (Port: port_number) (Connection failure, fabric limited to two switches) The switch cannot be connected to the fabric due to a license restriction. (C) (8700.0013) (Connection failure, fabric limited to two switches) The switch cannot be connected to the fabric due to license restriction. HP StorageWorks 8/20q and SN6000 Fibre Channel Switch Event Message Reference Guide 43

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52

HP StorageWorks 8/20q and SN6000 Fibre Channel Switch Event Message Reference Guide
43
(C) (8600.0017) (PortApp) (External
port license count exceeded, downing
external port
port_number
)
The named external port is down because
the number of licensed external ports has
been exceeded.
(C) (8600.0018) (PortApp) (External
port license became available,
re-starting downed external ports)
An external port that was previously down
because of insufficient port licenses is now
online.
(C) (8600.0019) (PortApp) (Internal
port license count exceeded, downing
internal port
port_number
)
A device attempted to log in to an internal
port, but a license was not available. A
license upgrade may be required, or a
license may be released by downing ports.
(C) (8600.001A) (PortApp) (Internal
port license became available,
re-starting downed internal ports)
A license has become available and ports
that had been previously downed to due to
unavailable licenses will be restarted.
(C) (8600.001B) (RX Seq Error D_ID
sequence_destination S_ID
sequence_source SEQ_ID sequence_ID
OX_ID originator_exchange RX_ID
recipient_exchange CMPLT
complete_status NFRAMES
frame_count)
An error was encountered while handling
the receive sequence referenced in the log
message. Contact your authorized
maintenance provider.
(C) (8700.0007) (EPort) (Port:
port_number
) (Received frame from
address not in Access Control List
(ACL) hard zone (src address =
FC_address
, dest address =
FC_address
))
The destination for the receive frame is in a
hard zone and the source is not. The frame
will not be forwarded.
(C) (8700.000D) (EPort) (Port:
port_number
) (Resetting
Inter-Switch Link (ISL), a time out
value has been reconfigured.)
R_A_TOV or E_D_TOV has been
reconfigured. E_Ports will be automatically
reset to inform the neighbor switch of the
change.
(C) (8700.000E) (EPort) (Port:
port_number
) (InteropCredit value
was reconfigured, resetting port.)
The
InteropCredit
parameter has
changed. The affected port will be
automatically reset.
(C) (8700.000F) (EPort) (Port:
port_number
) (Broadcast frame
received & broadcast disabled,
discarding broadcast frames.)
Broadcast is disabled and the switch has
received a broadcast frame. Enable
broadcast to receive broadcast frames.
(C) (8700.0010) (EPort) (Port:
port_number
) (Inter-Switch Link
(ISL) unstable. ISL init will be
held back until ISL up time is 5
seconds)
The Fabric inter-switch link (ISL) is unstable,
indicating that the media module or the
cable is bad.
(C) (8700.0011) (Eport) (Port:
port_number
) (Connection failure,
remote switch not compatible)
The remote switch is not compatible with the
local switch. The E_Port cannot exchange
switch capabilities with the remote switch.
(C) (8700.0012) (Eport) (Port:
port_number
) (Connection failure,
fabric limited to two switches)
The switch cannot be connected to the fabric
due to a license restriction.
(C) (8700.0013) (Connection
failure, fabric limited to two
switches)
The switch cannot be connected to the fabric
due to license restriction.
Table 5
Critical event messages and descriptions (Continued)
Icon
Event ID and message
Description