HP ProLiant 4500 Compaq ProLiant 4500R Rack-Mountable Servers Maintenance and - Page 13

Removal And Replacement, Procedures

Page 13 highlights

Chapter 2 2-1 REMOVAL AND REPLACEMENT PROCEDURES This guide provides detailed maintenance and service information for the Compaq ProLiant 4500R Rack-Mountable Server. RACK MOUNTABLE PRODUCTS SERVICE GUIDELINES Follow these guidelines when removing or replacing components. WARNING: Before loading any components in the rack, be sure that the rack leveling feet are extended to the floor, that the rack is stable and level, and that the full weight of the rack rests evenly on the leveling feet, not on the casters. Be sure that you have either attached the stabilizing feet or coupled multiple racks. WARNING: Always ensure that the rack is adequately stabilized before extending a component outside the rack, and extend only one component at a time. A rack may become unstable if more than one component is extended for any reason. WARNING: Be careful when pressing the component rail latches on both sides of the component. Pressing the latches in at the same time while sliding the component in on its rails, could pinch your fingers in the latch. n Allow a minimum clearance of 30 inches between the wall and the rack to provide adequate access. n Load the heaviest components first, and load the rack from the bottom up. Refer to the Rack Builder software to provide optimal installation order. n Ensure that the rails are properly aligned. Push the component completely into the rack and secure it in place with the four thumb screws on the component face plate before working on the next component. n Make sure the previously installed component is secured to the rack by its thumb screws; then install the next component. GENERAL REMOVAL AND REPLACEMENT GUIDELINES This manual provides subassembly/module-level removal and replacement procedures. After completing all necessary removal and replacement procedures, run the DIAGNOSTICS program to verify that all components operate properly. In addition, it may be necessary to run the Compaq System Configuration utility when installing new hardware. To service Compaq ProLiant 4500R Servers, you need: n Torx T-10 screwdriver n Torx T-15 screwdriver n Ethernet loopback plug n NetFlex loopback plug Maintenance and Service Guide

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92

Chapter 2
2-1
Maintenance and Service Guide
REMOVAL AND REPLACEMENT
PROCEDURES
This guide provides detailed maintenance and service information for the
Compaq ProLiant 4500R Rack-Mountable Server.
RACK MOUNTABLE PRODUCTS SERVICE
GUIDELINES
Follow these guidelines when removing or replacing components.
WARNING:
Before loading any components in the rack, be sure that the rack
leveling feet are extended to the floor, that the rack is stable and level, and that
the full weight of the rack rests evenly on the leveling feet, not on the casters.
Be sure that you have either attached the stabilizing feet or coupled multiple
racks.
WARNING:
Always ensure that the rack is adequately stabilized before
extending a component outside the rack, and extend only one component at a
time.
A rack may become unstable if more than one component is extended for
any reason.
WARNING:
Be careful when pressing the component rail latches on both
sides of the component. Pressing the latches in at the same time while sliding
the component in on its rails, could pinch your fingers in the latch.
n
Allow a minimum clearance of 30 inches between the wall and the rack to provide adequate
access.
n
Load the heaviest components first, and load the rack from the bottom up.
Refer to the Rack
Builder software to provide optimal installation order.
n
Ensure that the rails are properly aligned. Push the component completely into the rack and
secure it in place with the four thumb screws on the component face plate before working on
the next component.
n
Make sure the previously installed component is secured to the rack by its thumb screws; then
install the next component.
GENERAL REMOVAL AND
REPLACEMENT GUIDELINES
This manual provides subassembly/module-level removal and replacement procedures.
After
completing all necessary removal and replacement procedures, run the DIAGNOSTICS program
to verify that all components operate properly.
In addition, it may be necessary to run the
Compaq System Configuration utility when installing new hardware.
To service Compaq ProLiant 4500R Servers, you need:
n
Torx T-10 screwdriver
n
Torx T-15 screwdriver
n
Ethernet loopback plug
n
NetFlex loopback plug