HP ProLiant 4500 Compaq ProLiant 4500R Rack-Mountable Servers Maintenance and - Page 39

Server Manager/R board

Page 39 highlights

Diagnostic Tools 3-7 POST Error Messages Continued Error Code Beeps Probable Source of Problem 1151-Com Port 1 2S Address Assignment Conflict Both external and internal serial ports are assigned to COM1. 1152-Com Port 2, 3, 2S or 4 Address Assignment Conflict Both external and internal serial ports are assigned to COM2, COM3 or COM4. 1600-Server Manager/R Failure None Server Manager/R board failure. Error code displays after error message. 1610-Temperature 2S violation detected. Waiting for system to cool Ambient system temperature too hot. 1611-Fan failure 2S detected Required fan not installed or spinning. 1612-Primary power 2S supply failure. Primary power supply has failed. 1730-Fixed Disk 0 does not support DMA Mode None Fixed disk drive error. 1731-Fixed Disk 1 does not support DMA Mode None Fixed disk drive error. 1740-Fixed Disk 0 failed Set Block Mode command None Fixed disk drive error. 1741-Fixed Disk 1 failed Set Block Mode command None Fixed disk drive error. 1750-Fixed Disk 0 failed Identify command None Fixed disk drive error. 1751-Fixed Disk 1 failed Identify command None Fixed disk drive error. 1760-Fixed Disk 0 does not support Block Mode None Fixed disk drive error. Action Run the System Configuration Utility and correct. Run the System Configuration Utility and correct. Run Diagnostics. Replace failed assembly as indicated or contact your service provider. Check fan in system environment. Check fans. Replace power supply as soon as possible. Run the System Configuration Utility and correct. Run the System Configuration Utility and correct. Run the System Configuration Utility and correct. Run the System Configuration Utility and correct. Run the System Configuration Utility and correct. Run the System Configuration Utility and correct. Run the System Configuration Utility and correct. Continued Maintenance and Service Guide

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92

Diagnostic Tools
3-7
Maintenance and Service Guide
POST Error Messages
Continued
Error Code
Beeps
Probable Source of
Problem
Action
1151-Com Port 1
Address Assignment
Conflict
2S
Both external and
internal serial ports are
assigned to COM1.
Run the System
Configuration Utility and
correct.
1152-Com Port 2, 3,
or 4 Address
Assignment Conflict
2S
Both external and
internal serial ports are
assigned to COM2,
COM3 or COM4.
Run the System
Configuration Utility and
correct.
1600-Server
Manager/R Failure
None
Server Manager/R board
failure.
Error code
displays after error
message.
Run Diagnostics.
Replace failed assembly
as indicated or contact
your service provider.
1610-Temperature
violation detected.
Waiting for system
to cool
2S
Ambient system
temperature too hot.
Check fan in system
environment.
1611-Fan failure
detected
2S
Required fan not installed
or spinning.
Check fans.
1612-Primary power
supply failure.
2S
Primary power supply
has failed.
Replace power supply as
soon as possible.
1730-Fixed Disk 0
does not support
DMA Mode
None
Fixed disk drive error.
Run the System
Configuration Utility and
correct.
1731-Fixed Disk 1
does not support
DMA Mode
None
Fixed disk drive error.
Run the System
Configuration Utility and
correct.
1740-Fixed Disk 0
failed Set Block
Mode command
None
Fixed disk drive error.
Run the System
Configuration Utility and
correct.
1741-Fixed Disk 1
failed Set Block
Mode command
None
Fixed disk drive error.
Run the System
Configuration Utility and
correct.
1750-Fixed Disk 0
failed Identify
command
None
Fixed disk drive error.
Run the System
Configuration Utility and
correct.
1751-Fixed Disk 1
failed Identify
command
None
Fixed disk drive error.
Run the System
Configuration Utility and
correct.
1760-Fixed Disk 0
does not support
Block Mode
None
Fixed disk drive error.
Run the System
Configuration Utility and
correct.
Continued