HP ProLiant 4500 Compaq ProLiant 4500R Rack-Mountable Servers Maintenance and - Page 80

Table 5-1, System Unit Specifications

Page 80 highlights

5-2 Physical and Operating Specifications Table 5-1 System Unit Specifications Dimensions Height Depth Width Weight Input Requirements Nominal Line Voltage Range Input Voltage Rated Frequency Rated Input Current Power Supply Standard Redundant Temperature Range: Operating Shipping Heat Relative Humidity (non condensing) Operating Non operating Maximum Wet Bulb Temperature 12.25 in 23 in 19 in 62 lb 100-120 VAC 90 to 132 VAC 50-60 Hz 8 A 490 W 490 W 50° to 93° F -22° to 140° F 2696 BTU/hr 20% to 80% 5% to 90% 101.7° F 31.15 cm 58.42 cm 48.26 cm 28 kg 200-240 VAC 180 to 270 VAC 50-60 Hz 4 A 540 W 540 W 10° to 35° C -30° to 60° C 2696 BTU/hr 20% to 80% 5% to 90% 38.7° C Maintenance and Service Guide

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92

5-2
Physical and Operating Specifications
Maintenance and Service Guide
Table 5-1
System Unit Specifications
Dimensions
Height
12.25 in
31.15 cm
Depth
23 in
58.42 cm
Width
19 in
48.26 cm
Weight
62 lb
28 kg
Input Requirements
Nominal Line Voltage
100-120 VAC
200-240 VAC
Range Input Voltage
90 to 132 VAC
180 to 270 VAC
Rated Frequency
50-60 Hz
50-60 Hz
Rated Input Current
8 A
4 A
Power Supply
Standard
490 W
540 W
Redundant
490 W
540 W
Temperature Range:
Operating
50
°
to 93
°
F
10
°
to 35
°
C
Shipping
-22
°
to 140
°
F
-30
°
to 60
°
C
Heat
2696 BTU/hr
2696 BTU/hr
Relative Humidity (non condensing)
Operating
20% to 80%
20% to 80%
Non operating
5% to 90%
5% to 90%
Maximum Wet Bulb Temperature
101.7
°
F
38.7
°
C