HP ProLiant 4500 Compaq ProLiant 4500R Rack-Mountable Servers Maintenance and - Page 66
Soft Firmware Upgrade required
View all HP ProLiant 4500 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 66 highlights
3-34 Diagnostic Tools Physical drive (bay) X has failed The indicated physical drive has failed. Replace this drive. Physical drive (bay) X is undergoing drive recovery This drive is being rebuilt from the corresponding mirror or parity data. Normal operations should occur. Physical drive (bay) X was inadvertently replaced The physical drive was incorrectly replaced after another drive failed. Replace the drive that was incorrectly replaced and replace the original drive that failed. Do not run the System Configuration Utility and try to re-configure - data will be lost. Set configuration command issued The configuration of the IDA-2 has been updated. The array accelerator board remains disabled until it is reinitialized. Run the System Configuration Utility to reinitialize the array accelerator board. Soft Firmware Upgrade required DAAD has determined that your controller is running firmware that has been soft upgraded by the Compaq Upgrade Utility. However, the firmware running is not present on all drives. This could be caused by the addition of new drives in the system. Run the Compaq Upgrade Utility to place the latest firmware on all drives. Threshold for drive (bay) X violated This message indicates that a monitor and performance threshold for this drive has been violated. Check for the particular threshold that has been violated. Threshold violations for drive (bay) X This is a list of the individual thresholds that have been violated for this drive. The drive may need to be replaced. Run the Compaq Diagnostics Utility to determine if the drive has been initialized and the threshold violation warrants drive replacement. Unknown disable code A code was returned from the array accelerator board that DAAD does not recognize. Call your Authorized Compaq Reseller for the latest version of DAAD. Warning bit detected A monitor and performance threshold violation may have occurred. The status of a logical drive may not be OK. Check the other error messages for an indication of the problem. Maintenance and Service Guide