Diagnostic Tools 3-11 POST Error Messages Continued Error Code Beeps Probable Source of Problem 1792-Drive Array Reports Valid Data Found in Array Accelerator. Data will automatically be written to drive array. None This indicates that while the system was in use, power was interrupted while data was in the Array Accelerator memory. Power was then restored within eight to ten days, and the data in the Array Accelerator was flushed to the drive array. 1793-Drive Array Array Accelerator Battery Depleted Data Lost (Error message 1794 also displays.) None This indicates that while the system was in use, power was interrupted while data was in the Array Accelerator memory. Array Accelerator batteries failed. Data in Array Accelerator has been lost. 1794-Drive Array Array Accelerator Battery Charge Low. Array Accelerator is temporarily disabled. Array Accelerator will be re-enabled when battery reaches full charge. None This is a warning that the battery charge is below 75%. Posted writes are disabled. 1795-Drive Array Array Accelerator Configuration Error. Data does not correspond to this drive array. Array Accelerator is temporarily disabled. None This indicates that while the system was in use, power was interrupted while data was in the Array Accelerator memory. The data stored in the Array Accelerator does not correspond to this drive array. Action No action necessary; no data has been lost. Perform orderly system shutdowns to avoid data remaining in the Array Accelerator. Power was not restored within eight to ten days. Perform orderly system shutdowns to avoid data remaining in the Array Accelerator. Replace the Array Accelerator board if batteries do not recharge within 36 power-on hours. 1. Match the Array Accelerator to the correct drive array. -Or2. Run the System Configuration Utility to clear the data in the Array Accelerator. Continued Maintenance and Service Guide