HP ProLiant 4500 Compaq ProLiant 4500R Rack-Mountable Servers Maintenance and - Page 31
Speaker
View all HP ProLiant 4500 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 31 highlights
Removal and Replacement Procedures 2-19 5. Remove the fan retaining screw (1). 6. Slide the subpanel forward far enough to gain access to the fan. 7. Remove fan. 8. Reverse steps to install new fan. Speaker Figure 2-19. Removing the Speaker 1. Extend the server out from the rack to the locked position and remove cover plate. 2. Remove the Y brace. 3. Disconnect the speaker cable from the system board. 4. Slide the subpanel forward far enough to gain access to the speaker. 5. Squeeze the speaker retaining spring clip pull forward to release the speaker. 6. Remove the speaker. 7. Reverse steps to install the new fan. Maintenance and Service Guide
Removal and Replacement Procedures
2-19
Maintenance and Service Guide
5.
Remove the fan retaining screw (1).
6.
Slide the subpanel forward far enough to gain access to the fan.
7.
Remove fan.
8.
Reverse steps to install new fan.
Speaker
Figure 2-19.
Removing the Speaker
1.
Extend the server out from the rack to the locked position and remove cover plate.
2.
Remove the Y brace.
3.
Disconnect the speaker cable from the system board.
4.
Slide the subpanel forward far enough to gain access to the speaker.
5.
Squeeze the speaker retaining spring clip pull forward to release the speaker.
6.
Remove the speaker.
7.
Reverse steps to install the new fan.