HP ProLiant 4500 Compaq ProLiant 4500R Rack-Mountable Servers Maintenance and - Page 50

Table 3-7, Diskette Drive Error Test Codes, Table 3-8, Monochrome Video Board Test Error Codes

Page 50 highlights

3-18 Diagnostic Tools Error Code 600-xx 601-xx 602-xx 603-xx 604-xx 605-xx 606-xx 607-xx 608-xx 609-xx 610-xx 694-xx 697-xx 698-xx 699-xx Table 3-7 Diskette Drive Error Test Codes Description Recommended Action Diskette ID drive types test failed Diskette format failed Diskette read test failed Diskette write/read/compute test failed Diskette random seek test failed Diskette ID media failed Diskette speed test failed Diskette wrap test failed Diskette write protect test failed Diskette reset controller test failed The following steps apply to error codes 600-xx through 698-xx: 1. Replace the diskette and re-test. 2. Check and/or replace the diskette power and signal cables and re-test. 3. Replace the diskette drive and re-test. 4. Replace the system board and re-test. Diskette change line test failed Pin 34 is not cut on 360 KB diskette drive Diskette type error Diskette drive speed not within limits Diskette drive/media ID error The following steps apply to 699-xx error codes: 1. Replace the media and re-test. 2. Run the Configuration utility and re-test. Error Code 802-xx 824-xx Table 3-8 Monochrome Video Board Test Error Codes Description Video memory test failed Monochrome video text mode test failed Recommended Action The following steps apply to error codes 802-xx and 824-xx: 1. Replace monitor and re-test. 2. Replace the Advanced VGA board and re-test. 3. Replace monochrome board and re-test. 4. Replace the system board and re-test. Maintenance and Service Guide

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92

3-18
Diagnostic Tools
Maintenance and Service Guide
Table 3-7
Diskette Drive Error Test Codes
Error
Code
Description
Recommended Action
600-xx
601-xx
602-xx
603-xx
604-xx
605-xx
606-xx
607-xx
608-xx
609-xx
610-xx
694-xx
697-xx
698-xx
Diskette ID drive types test failed
Diskette format failed
Diskette read test failed
Diskette write/read/compute test failed
Diskette random seek test failed
Diskette ID media failed
Diskette speed test failed
Diskette wrap test failed
Diskette write protect test failed
Diskette reset controller test failed
Diskette change line test failed
Pin 34 is not cut on 360 KB diskette drive
Diskette type error
Diskette drive speed not within limits
The following steps apply to error
codes 600-xx through 698-xx:
1.
Replace the diskette and re-test.
2.
Check and/or replace the diskette
power and signal cables
and re-test.
3.
Replace the diskette drive
and re-test.
4.
Replace the system board
and re-test.
699-xx
Diskette drive/media ID error
The following steps apply to 699-xx
error codes:
1.
Replace the media and re-test.
2.
Run the Configuration utility
and re-test.
Table 3-8
Monochrome Video Board Test Error Codes
Error
Code
Description
Recommended Action
802-xx
824-xx
Video memory test failed
Monochrome video text mode test failed
The following steps apply to error
codes 802-xx and 824-xx:
1.
Replace monitor and re-test.
2.
Replace the Advanced VGA
board and re-test.
3.
Replace monochrome board
and re-test.
4.
Replace the system board