HP StorageWorks 1606 HP StorageWorks Fabric OS 6.3.0c Release Notes (5697-0361 - Page 28
When rebooting a DC SAN director or DC04 SAN director with DC SAN 10/24 FCoE blade
View all HP StorageWorks 1606 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 28 highlights
version disrupts traffic through the blades. HA Failover of CP blades in either of these directors disrupts traffic through the 10/24 FCoE blades. • Upgrades from Fabric OS 6.3 to future releases will be nondisruptive to data traffic and will have behavior similar to a CP failover; ethsw remains unchanged. • Downgrade from Fabric OS 6.3 to 6.1.2_cee1 is disruptive if ethsw is enabled on Fabric OS 6.3. • Downgrade from Fabric OS 6.3 to 6.1.2_cee1 is nondisruptive if ethsw has never been enabled with Fabric OS 6.3. • Connecting a 2408 FCoE Converged Network Switch to an FCR-capable switch with fcrbcast config enabled will cause a storm of broadcast traffic, resulting in termination of iswitchd. • When rebooting a DC SAN director or DC04 SAN director with DC SAN 10/24 FCoE blade, Qlogic CNA and LSAN zoning, the switch becomes unresponsive for a period of time. This is due to the CNA sending excessive MS queries to the switch. 28