Name Server daemon (nsd) panic occurs after enabling frame redirection. Fixed in Fabric OS 6.3.0 Workaround prior to code change: Delay executing a cfgenable after a cfgsave when there is frame RD zone. RTWR error when going to translate domain. Fixed in Fabric OS 6.3.0 400 Multiprotocol Router VE port doesn't recover after WAN issues. Fixed in Fabric OS 6.3.0 In a large fabric (50+ switches), simultaneously disabling and enabling all switches could result in some switches stuck in F2 (unconfirmed) state. Fixed in Fabric OS 6.3.0 Workaround prior to code change: Disable and enable the switches that are stuck in F2 (domain ID not yet confirmed) state independently. In some rare scenarios, when HA Failover performed prior to Name Server being in sync, RSCNs were delivered. Test tool reports data miscompare during an overnight run. Fixed in Fabric OS 6.3.0 Fixed in Fabric OS 6.3.0 Need for synchronization between DCBX FCoE priorities with that of Fixed in Fabric OS 6.3.0 PFCs enabled. FrustatusChanged trap and fruhistorytrap are not received when a slot Fixed in Fabric OS 6.3.0 is removed or inserted. Encrypted LUN gets into internal Encryption Engine (EE) LUN State: Disabled (key not in sync) as a result of rekeying and HAC/DEK cluster Fixed in Fabric OS 6.3.0 failover and failback. As a result of I/O and crypto operations, three LUNs are in "Key ID Unvailable" state and one LUN indicates that inquiry failed. Fixed in Fabric OS 6.3.0 Workaround prior to code change: Reboot the Encryption Engine (EE). DMM used license can be reset after netinstall of Fabric OS. Fixed in Fabric OS 6.3.0 4 Gb SAN Switch for HP c-Class BladeSystem AG may login to DC SAN Director with wrong pwwn. Fixed in Fabric OS 6.3.0 Workaround prior to code change: Reboot AG. OpenVMS init command is not correctly supported. Fixed in Fabric OS 6.3.0 In Fabric OS 6.2, OID for connUnitType no longer returns the correct Fixed in Fabric OS 6.3.0 access gateway mode status. System panic on stand by cp after an hafailover. Fixed in Fabric OS 6.3.0 Default Fabric Watch alarm value needs to be modified. Fixed in Fabric OS 6.3.0 Port fence disabled ports that are running diagtest and triggered blade fault during blade POST. Addressing mode NVP is not available in switch.html page. Fixed in Fabric OS 6.3.0 Fixed in Fabric OS 6.3.0 HP StorageWorks Fabric OS 6.3.0c Release Notes 51