HP StorageWorks 1606 HP StorageWorks Fabric OS 6.3.0c Release Notes (5697-0361 - Page 62
fencing policy for F_Port. B. Existing, DC04 SAN Director.
View all HP StorageWorks 1606 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 62 highlights
While performing security related fabric wide operations if fabric becomes unstable, user might observe verify on standby. Fixed in Fabric OS 6.3.0 Workaround prior to code change: System will recover. Setting the E-Net portname on the Primary CP does not get copied over to the standby CP. Fixed in Fabric OS 6.3.0 NPIV devices on a single port are spread across effective and McDATA default configurations, only devices from default configuration can establish communication. Fixed in Fabric OS 6.3.0 Workaround prior to code change: Do not overlap effective and default zones on the same NPIV port, following best practices guidelines. Access Gateways connected to EOSc in a mixed fabric (Fabric OS and EOS) are not shown in DCFM. Fixed in Fabric OS 6.3.0 Not able to add EE monitor on port 1 after firmware upgrade from 6.1.0c to 6.2.0 on 400 Multiprotocol router. Fixed in Fabric OS 6.3.0 Nsinfo.htm returns NPIV info as Physical if non-VF switch is connected Fixed in Fabric OS 6.3.0 to VF enabled platform. CP experienced a kenel panic "Oops: kernel access of bad area, sig: Fixed in Fabric OS 6.3.0 11 [#1]". Fruclass in fru table and fruhistoryclass in fruhistorytable of HA MIB shows other(1) for CP slot instead of cp(4) for DC SAN Director and DC04 SAN Director. Fixed in Fabric OS 6.3.0 CPstatus change trap is not generated on issuing HA failover for 4/256 SAN Director, but the failover happens and the CP status change oid Fixed in Fabric OS 6.3.0 returns changed values. Fabric OS CLI doesn't allow Port fencing policy addition for F_Port when there are no F_ports on the switch. Fixed in Fabric OS 6.3.0 Workaround prior to code change: A. DCFM can be used to add the port fencing policy for F_Port. B. Existing Fabric OS CLI can always be used to add port fencing policy after bringing up F_Port on a switch. Adding port fencing policy for F_Port makes sense only when there are F ports on a switch and anyway the existing CLI behavior takes care of this. Not getting GbE ports while performing EnumerateAssociatedInstances Fixed in Fabric OS 6.3.0 on Brocade_LogicalSwitch. Switch doesn't commit after firmwareDownload fail as 0x23 (time Fixed in Fabric OS 6.3.0 out). Appropriate message is not shown in the message box, when the "Details" button in the "Service" tab of "HA" window is clicked. Fixed in Fabric OS 6.3.0 High Availability: The error message thrown is not relevant or meaningful, when the values for E_D_TOV and R_D_TOV in the "Configure" Fixed in Fabric OS 6.3.0 tab of "Switch admin", are changed. Incorrect output from agshow command. Fixed in Fabric OS 6.3.0 62