HP StorageWorks 1606 HP StorageWorks Fabric OS 6.3.0c Release Notes (5697-0361 - Page 52
Class 2 ACK is not forwarded from F_Port to N_Port in Access Gate
View all HP StorageWorks 1606 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 52 highlights
Class 2 ACK is not forwarded from F_Port to N_Port in Access Gate- Fixed in Fabric OS 6.3.0 way. MS Platform dB is activated after warm recovery of firmwaredown- Fixed in Fabric OS 6.3.0 load. Inconsistencies seen for topologyshow and islshow bandwidth on 8/80 and 8/8 or 8/16 switches. Fixed in Fabric OS 6.3.0 FICON XRC Emulation error handling OOO Status Frames. Fixed in Fabric OS 6.3.0 Workaround prior to code change: Option 1: Deactivate all paths that utilize the same device ports and reactivate at the same time. Option 2: Disable FICON XRC emulation. HIL-1610 WARNING appeared on 8/40 switch units after power cycle. Fixed in Fabric OS 6.3.0 Workaround prior to code change: Ignore the warning - it is innocuous when seen right at boot up time. It results from a solitary spurious sensor reading that is below minimum. Temperature sensor reporting spurious solitary readings which leads to the CRITICAL HIL-1502 message, without having first gone through the HIL-1501 warning. Fixed in Fabric OS 6.3.0 Workaround prior to code change: Ignore isolated / spurious High Temperature CRITICAL errors when not preceded by warnings. Unable to get F Ports(Trunk Ports) data. Fixed in Fabric OS 6.3.0 On some of 2408 FCoE Converged Network switches, DIAGPOST is Fixed in Fabric OS 6.3.0 failing due to loss of sync. Processor rebooted - Software Fault:ASSERT when frame size received Fixed in Fabric OS 6.3.0 is too big. Need to support a command "clear logging" to clear all debug log messages accumulated. Fixed in Fabric OS 6.3.0 Workaround prior to code change: Go to FOS mode and issue an errclear command. CLI output consistency and input validation issues around key lifespan option of a LUN. Fixed in Fabric OS 6.3.0 Workaround prior to code change: Input validation issues. Requires the user to provide valid input. High Availability : User is able to change the "desired distance" for long distance "L0". User should not be able to change the "Desired distance" if the "Long distance" value is "L0". It should always be "N/A" for L0. Fixed in Fabric OS 6.3.0 After firmware upgrade, FC FastWrite traffic sometimes fails. Fixed in Fabric OS 6.3.0 A few VERIFYs are dumped out on DC SAN Director and Multiprotocol Router Blade EX port stuck without showing switch name of the edge Fixed in Fabric OS 6.3.0 fabric switch etc during edge switch firmwareupgrade. 52