HP StorageWorks 1606 HP StorageWorks Fabric OS 6.3.0c Release Notes (5697-0361 - Page 49

Port Fencing - E_Port Class Link Resets are not fencing.

Page 49 highlights

2408 FCoE Converged Network switch freezes with jumbo frame blast. Fixed in Fabric OS 6.3.0 FDMI Database information not showing proper information after dis- Fixed in Fabric OS 6.3.0 abling the port in AG that is connected to HBA. Host with Fibrechannel Fastwrite (FCFW) enabled has problems with Fixed in Fabric OS 6.3.0 port disable/enable of HBA ports. Switch Kernel panics when performing VMware VMotion (vport migra- Fixed in Fabric OS 6.3.0 tion). While rekey operations are in progress, disrupting the I/O sync link Fixed in Fabric OS 6.3.0 causes rekey operations to hang. In an atypical test configuration, system reboot observed on one of two 2408 FCoE Converged Network switches configured as point-topoint FC connections. Fixed in Fabric OS 6.3.0 Port Fencing - E_Port Class Link Resets are not fencing. Fixed in Fabric OS 6.3.0 There is a small timing window that devices might send PLOGI earlier Fixed in Fabric OS 6.3.0 than route is setup and cause PLOGI drop in single switch fabric. 2408 FCoE Converged Network switch has a rolling reboot when Fixed in Fabric OS 6.3.0 deleting the active fcoe logincfg from conflicting logingroup database. After rebooting one Encryption SAN Switch of a HAC that has connectivity to the physical targets and initiators, all the crypto targets are Fixed in Fabric OS 6.3.0 lost in the HAC cluster. IPAD-5000 messages with error code "105" showing up on most platforms in AG fabrics. Possible Memory Leak scenarios. Fixed in Fabric OS 6.3.0 RLIRs with LOL is being generated on 8 Gb channels during CEC IML Fixed in Fabric OS 6.3.0 Fail to label tape w/ error: ERROR, SYS, Crypto tape receives service failure in tape_cmd_pre_execution_scsi_chk: PI BLK size > RBL, 0x0, Fixed in Fabric OS 6.3.0 tape_util.c, line: 5002. User entered FRU number via CLI is not being modified. Fixed in Fabric OS 6.3.0 Authentication is getting failed after 15 minutes if we configured ex- Fixed in Fabric OS 6.3.0 ternal authentication like LDAP or Radius server. Tape pipelining code on PI side does not close exchange upon a ELS Fixed in Fabric OS 6.3.0 RJT response to REC -- "invalid oxid/rxid combo". Detected unexpected termination of Remote Procedure Call (RPC) daemon. Fixed in Fabric OS 6.3.0 Persistent IU pacing feature in 3rd party device trigger issues with tape Fixed in Fabric OS 6.3.0 emulation. During stress test overnight run of rekey and ISL disable/enable, the test tool exited on write failure to encrypted LUNs. Fixed in Fabric OS 6.3.0 Encryption SAN Switch goes to 'faulty' state after test cycle that alternately reboots each Encryption SAN Switch in the configuration every Fixed in Fabric OS 6.3.0 5 minutes. HP StorageWorks Fabric OS 6.3.0c Release Notes 49

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76

Fixed in Fabric OS 6.3.0
2408 FCoE Converged Network switch freezes with jumbo frame
blast.
Fixed in Fabric OS 6.3.0
FDMI Database information not showing proper information after dis-
abling the port in AG that is connected to HBA.
Fixed in Fabric OS 6.3.0
Host with Fibrechannel Fastwrite (FCFW) enabled has problems with
port disable/enable of HBA ports.
Fixed in Fabric OS 6.3.0
Switch Kernel panics when performing VMware VMotion (vport migra-
tion).
Fixed in Fabric OS 6.3.0
While rekey operations are in progress, disrupting the I/O sync link
causes rekey operations to hang.
Fixed in Fabric OS 6.3.0
In an atypical test configuration, system reboot observed on one of
two 2408 FCoE Converged Network switches configured as point-to-
point FC connections.
Fixed in Fabric OS 6.3.0
Port Fencing - E_Port Class Link Resets are not fencing.
Fixed in Fabric OS 6.3.0
There is a small timing window that devices might send PLOGI earlier
than route is setup and cause PLOGI drop in single switch fabric.
Fixed in Fabric OS 6.3.0
2408 FCoE Converged Network switch has a rolling reboot when
deleting the active fcoe logincfg from conflicting logingroup database.
Fixed in Fabric OS 6.3.0
After rebooting one Encryption SAN Switch of a HAC that has con-
nectivity to the physical targets and initiators, all the crypto targets are
lost in the HAC cluster.
Fixed in Fabric OS 6.3.0
IPAD-5000 messages with error code "105" showing up on most
platforms in AG fabrics. Possible Memory Leak scenarios.
Fixed in Fabric OS 6.3.0
RLIRs with LOL is being generated on 8 Gb channels during CEC IML
Fixed in Fabric OS 6.3.0
Fail to label tape w/ error: ERROR, SYS, Crypto tape receives service
failure in tape_cmd_pre_execution_scsi_chk: PI BLK size > RBL, 0x0,
tape_util.c, line: 5002.
Fixed in Fabric OS 6.3.0
User entered FRU number via CLI is not being modified.
Fixed in Fabric OS 6.3.0
Authentication is getting failed after 15 minutes if we configured ex-
ternal authentication like LDAP or Radius server.
Fixed in Fabric OS 6.3.0
Tape pipelining code on PI side does not close exchange upon a ELS
RJT response to REC -- "invalid oxid/rxid combo".
Fixed in Fabric OS 6.3.0
Detected unexpected termination of Remote Procedure Call (RPC)
daemon.
Fixed in Fabric OS 6.3.0
Persistent IU pacing feature in 3rd party device trigger issues with tape
emulation.
Fixed in Fabric OS 6.3.0
During stress test overnight run of rekey and ISL disable/enable, the
test tool exited on write failure to encrypted LUNs.
Fixed in Fabric OS 6.3.0
Encryption SAN Switch goes to 'faulty' state after test cycle that altern-
ately reboots each Encryption SAN Switch in the configuration every
5 minutes.
HP StorageWorks Fabric OS 6.3.0c Release Notes
49