HP StorageWorks 1606 HP StorageWorks Fabric OS 6.3.0c Release Notes (5697-0361 - Page 71
Fabric OS 6.3.0b fixes, lists defects closed in the Fabric OS 6.3.0b firmware release.
View all HP StorageWorks 1606 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 71 highlights
Software verify error detected appears on console during upgrade to 6.3.0 from RC builds on HP StorageWorks 8/80 SAN Fixed in Fabric OS 6.3.0a Switch. This issue will not be seen in the field. Retransmit and Out of Order counters displayed in the portshow fciptunnel command do not show correct values. Fixed in Fabric OS 6.3.0a If the first circuit in the first tunnel is not numbered 0, portshow fciptunnel all -c displays incorrect value (adds line 16 0 un- Fixed in Fabric OS 6.3.0a knwn Disable ---- 0s 0.00 0.00 0 0/0 0). With 1606 Extension SAN Switch or Multiprotocol Extension Blade, FCIP configuration cannot be restored to default setting by using configdefault, even after chassis reboot. Fixed in Fabric OS 6.3.0a HP StorageWorks Encryption SAN Switch or encryption blade drops frames received from the host when the back-end tape becomes unresponsive. Fixed in Fabric OS 6.3.0a HP StorageWorks Multiprotocol Extension Blade faceplate image in WebTools 10-GbE ports should be renamed as XGE ports. Fixed in Fabric OS 6.3.0a ifName value returned for xGBE port in WebTools does not match CLI output. Fixed in Fabric OS 6.3.0a If the ITL nexus in tape (target containers with initiator) to handle multiplex/multistream environment is greater than 200, decreased performance is seen for some containers. Fixed in Fabric OS 6.3.0a Workaround prior to code change: Reduce IT configurations (target containers with initiators) to 200. NPIV tape devices may not be seen by hosts due to name server not sending subsequent PLOGI ACC following a sequence where NPIV device sends LOGO before link down. Fixed in Fabric OS 6.3.0a GbE ports on HP StorageWorks Extension SAN Switch or Multiprotocol Extension Blade will continually showail No_Sync status if non-B-series SFP was inserted and then replaced with B-series SFP. Fixed in Fabric OS 6.3.0a Workaround prior to code change: Use portdisable and portenable after inserting the supported SFP. Copper 1-GbE SFP can get into an illegal state on Extension SAN Switch where no LED light is shown, but port is online and working. Fixed in Fabric OS 6.3.0a Fabric OS 6.3.0b fixes Table 10 lists defects closed in the Fabric OS 6.3.0b firmware release. Table 10 Fabric OS 6.3.0b closed defects Closed defect summary Solution When an unsupported SFP is installed in an HP StorageWorks DC SAN Director Multiprotocol Extension Blade, the amber LED flashes to indicate a fault, as it should. However, if an optical cable is plugged into the SFP, the amber LED extinguishes. The actual port status is unchanged. Fixed in Fabric OS 6.3.0b HP StorageWorks Fabric OS 6.3.0c Release Notes 71