HP StorageWorks 1606 HP StorageWorks Fabric OS 6.3.0c Release Notes (5697-0361 - Page 67
Onboard Administrator used to manage 8 Gb SAN Switch for, Delete and re-install EE Monitors.
View all HP StorageWorks 1606 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 67 highlights
Changing configuration using configure or configDownload when systemVerification is executed could lock out the systemVerification from being executed subsequently. Fixed in Fabric OS 6.3.0 Workaround prior to code change: Do not update the configuration when systemVerification is running. If user accidentally changes configuration when the command was executing, use "burninlevel 0" to recover from this situation. Channel definition errors; time out on QSA Response due to excessive Fixed in Fabric OS 6.3.0 link incidents. The ifNumber does not match the number of entries in the ifTable for Fixed in Fabric OS 6.3.0 the logical switches with LISL. Newly created LS should inherit NTP server setting of Default LS. Fixed in Fabric OS 6.3.0 Workaround prior to code change: Don't use date command in non-default logical swtich. Allowed to add a F_Port TT Monitor to mirror port, however no counters Fixed in Fabric OS 6.3.0 display. Virtual nodes on the same switch port may not be able to communicate Fixed in Fabric OS 6.3.0 due to missing RSCNs and the CAM not be programmed. This is not Workaround prior to code change: a likely scenario. Toggle the physical port. Command portcfgdefault performed on an internal F_Port will convert that F_Port into an N_Port. Fixed in Fabric OS 6.3.0 Workaround prior to code change: When the system is working well, save that configuration somewhere so that it can be reapplied instead of relying on portcfgdefault. Fixed in Fabric OS 6.3.0 EE monitor counter is not incrementing after firmware upgrade to 6.2.0. Workaround prior to code change: Delete and re-install EE Monitors. ISL monitor total transmit and number of destination domains monitored Fixed in Fabric OS 6.3.0 counters show 0 when traffic is running thru this ISL. SNMP: The swNs Table does not list all the name server entries. Fixed in Fabric OS 6.3.0 Interopmode 2 - Value other than 0 or 1 in configdownload file will Fixed in Fabric OS 6.3.0 enable default zone; I was expecting an error message. IP monitor shows number of SCSI frames after deleting a SCSI filter monitor and adding IP monitor on the same port. Fixed in Fabric OS 6.3.0 Onboard Administrator used to manage 8 Gb SAN Switch for BladeSystem c-Class is not able to read the switchname. Fixed in Fabric OS 6.3.0 Workaround prior to code change: Switch name can be displayed from Fabric OS CLI command switchname. Statsclear does not clear porterrshow statistic data for field "link fail " on 6-port 10Gb/s ISL blade. Fixed in Fabric OS 6.3.0 HP StorageWorks Fabric OS 6.3.0c Release Notes 67