HP StorageWorks 1606 HP StorageWorks Fabric OS 6.3.0c Release Notes (5697-0361 - Page 43
Initial setup of encrypted LUNs, Fabric OS 6.3.0 fixes, output
View all HP StorageWorks 1606 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 43 highlights
Initial setup of encrypted LUNs IMPORTANT: While performing first-time encryption to a LUN with more than one initiator active at the time, rekey operations slow to a standstill. Define LUNs for a single initiator at a time to avoid this occurrence. NOTE: When configuring multipath LUNs, care should be taken to add LUN 0 on all of the paths, subject to the following considerations: • If LUN 0 presented by the back-end target is a controller LUN (not a disk LUN; that is, not visible in the discoverLUN output), add LUN 0 to the container as a clear text LUN. Make sure all of the paths have this LUN 0 added for MPIO operation (EVA configuration, for example). • If LUN 0 presented by the back-end target is a disk LUN, LUN 0 can be added to the container either as clear text or encrypted (MSA configuration, for example). • For HP-UX, LUN 0 can appear as 0x0 or 0x400, but both of them are LUN 0 only and should be treated alike. Fabric OS 6.3.0 fixes Table 8 lists defects closed in the Fabric OS 6.3.0 firmware release. All fixes from Fabric OS 6.1.2b and 6.2.0g are merged into the 6.3.0 release. Table 8 Fabric OS 6.3.0 closed defects Closed defect summary FICON emulation failing. Solution Fixed in Fabric OS 6.3.0 Pending Merge:VTs/VIs disappear when rebooting the HP StorageWorks Encryption SAN Switch that has all the physical connections to targets and initiators. As a result of creating a cryptoLUN, a host can use a target even though they are not in the same zone. Fixed in Fabric OS 6.3.0 Fixed in Fabric OS 6.3.0 Workaround prior to code change: If a Host and Target are no longer zoned together, the user should also remove the associated container (the frame redirect zone) for this Host/Target pair. This prevents Host/Target communication for this pair via the container (that is, redirection). FICUD panic and reboot on DCX occurs after executing a host com- Fixed in Fabric OS 6.3.0 mand to display the switch. HP StorageWorks Fabric OS 6.3.0c Release Notes 43