HP StorageWorks 1606 HP StorageWorks Fabric OS 6.3.0c Release Notes (5697-0361 - Page 69
Fabric OS 6.3.0a fixes, lists defects closed in the Fabric OS 6.3.0a firmware release.
View all HP StorageWorks 1606 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 69 highlights
During stress-to-fail testing of Cold Start/Recovery on a switch with multiple Logical Switches, the local Name Server misses some device entries. Fixed in Fabric OS 6.3.0 Workaround prior to code change: Perform switchdisable/enable on the affected switches. Same device ( WWN ) is visiable in more than 2 fabric using VF function and VT not getting imported. Fixed in Fabric OS 6.3.0 Port Auto Disable - Wrong message when disabling port auto disable. Fixed in Fabric OS 6.3.0 After few hafailovers, FC fast write I/O times out and a few unexpected frame drops are seen on 1 to 2 ports out of 7-8 ports running. Fixed in Fabric OS 6.3.0 Workaround prior to code change: Disable FCFW feature or limit the number of HA Failover sequences to times when IO is not active. Desired distance is editable for the long distance mode L0:Normal initially when the page loads. Fixed in Fabric OS 6.3.0 Fabric OS 6.3.0a fixes Table 9 lists defects closed in the Fabric OS 6.3.0a firmware release. Table 9 Fabric OS 6.3.0a closed defects Closed defect summary Solution Switch panic occurs due to Out Of Memory condition when manage- Fixed in Fabric OS 6.3.0a ment application issues repeated FCR LUN emulation queries via SMI, Workaround prior to code change: or when polling a switch that had its password changed multiple times. Disable SMI agents. sysshutdown on 8Gb SAN Switch for HP BladeSystem c-Class may cause panic and reboots. Fixed in Fabric OS 6.3.0a Workaround prior to code change: Use the CLI shutdown command. HP StorageWorks Multiprotocol Router Blade heartbeat stops, causing a reboot while traffic is running over FCIP links. This may cause CP Fixed in Fabric OS 6.3.0a failover, disrupting traffic only on the router blade. After changing the domain offset followed by hafailover on CP1 in interopmode 2 on DC SAN Director, DC04 Director or 4/256 Director, Unknown LSR type messages generated by CP0 scroll continuously on console log. Fixed in Fabric OS 6.3.0a Workaround prior to code change: Perform hafailover to other CP. Under heavy traffic on 10-Gb tunnel on HP StorageWorks DC SAN Director Multiprotocol Extension Blade running in compression mode, back-to-back tunnel parameter modification can cause FCIP traffic to halt due to timing issue with internal buffers. This can also happen on 1-GbE ports, but over a longer I/O run than on 10-GbE ports. Fixed in Fabric OS 6.3.0a I/O times out and stops when running across same VE link as other I/O when failover is done on a trunked EX_Port with HP StorageWorks 1606 Extension Switch or Multiprotocol Extension Blade. Fixed in Fabric OS 6.3.0a HP StorageWorks Fabric OS 6.3.0c Release Notes 69