HP StorageWorks 1606 HP StorageWorks Fabric OS 6.3.0c Release Notes (5697-0361 - Page 48
fddcfg -fabwideset, Portswap, portdisable, Workaround prior to code change
View all HP StorageWorks 1606 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 48 highlights
Command fddcfg -fabwideset and other security commands fail Fixed in Fabric OS 6.3.0 with RCS transaction error. With tape pipelining active, the switch may return a good status without Fixed in Fabric OS 6.3.0 sending data. DC SAN Director ASIC parity errors, ICL CRC's and IFCC's on overnight workload. Fixed in Fabric OS 6.3.0 Host detecting IFCCs errors to CUP Port. Fixed in Fabric OS 6.3.0 Sshd allows admin login to execute root level Linux commands but not admin CLI commands. Fixed in Fabric OS 6.3.0 Workaround prior to code change: A workaround to facilitate execution of admin level CLI commands using ssh, is to use syntax similar to: ssh -l admin 192.168.1.12 "rbash --login -c 'switchshow'" Or if a command is needed that works on both older (correctly operating) Fabric OS and the newer/affected FOS: ssh -l admin 192.168.1.12 "switchshow || rbash --login -c 'switchshow'" Encryption SAN Switch goes faulty as a result of alternately rebooting the two Encryption SAN Switches that have all the physical connectiv- Fixed in Fabric OS 6.3.0 ities to the targets and initiators. Encryption SAN Switch went Faulty when starting traffic. Fixed in Fabric OS 6.3.0 SAK/IRNDUP fails with Port Address Name miscompare on CUP Port Fixed in Fabric OS 6.3.0 x'FE' Detected termination of process fabricd:4820 Fixed in Fabric OS 6.3.0 Pending Merge: Disconnecting and reconnecting the ISL on Encryption SAN Switch while rekey in progress may result in new key creation Fixed in Fabric OS 6.3.0 failure. Encryption SAN Switch shows Encryption Engine busy when continuously and repeatedly disabling and enableing I/O sync ports of the Encryption SAN Switch. Fixed in Fabric OS 6.3.0 Node descriptors are missing for DC SAN Director and DC04 SAN Fixed in Fabric OS 6.3.0 Director. Tape pipelining code begins to randomly send only data frames in an Fixed in Fabric OS 6.3.0 exchange to tape drive. Partitioned DC04 SAN Director panicked after reset allegiance issued Fixed in Fabric OS 6.3.0 by multiple hosts. Rolling ASSERT+PANIC on DC SAN Director with DC Switch Encryption Fixed in Fabric OS 6.3.0 blade faulty when going from 6.1.2 to 6.2.0d. Portswap not working for ports 32-47 on 48 port blade. Fixed in Fabric OS 6.3.0 VI to PT routes are deleted following portdisable and portenable Fixed in Fabric OS 6.3.0 on a 48-port 4Gb blade. 48