HP StorageWorks 1606 HP StorageWorks Fabric OS 6.3.0c Release Notes (5697-0361 - Page 54

Director or DC04 SAN Director., Fixed in Fabric OS 6.3.0

Page 54 highlights

IPv6 Address dropped from ag --show. Fixed in Fabric OS 6.3.0 Workaround prior to code change: Issue switchdisable and switchenable, which causes the IPv6 Address again to be presented. Port statistics details are not getting refreshed for EX ports. Fixed in Fabric OS 6.3.0 WebTools Switch Admin: QoS: User defined priority group 0-7 does not show up in the drop down for priority group id. Fixed in Fabric OS 6.3.0 Workaround prior to code change: Use CLI to map user defined priority group to a CoS. 8/8 or 8/16 returned invalid value for swFCPortFlag MIB object Fixed in Fabric OS 6.3.0 from 8/8 or 8/16 on SNMP manager. MAC learning/flushing times are very slow on 2408 FCoE CN Switch Fixed in Fabric OS 6.3.0 Switch. Switch crashed on sending LOGO from Finisar LT. Fixed in Fabric OS 6.3.0 Virtual Fabrics 6.2.0c when XISL use is enabled base logical switch in switchshow shows Allow XISL Use as "off" open RFE 1249. Fixed in Fabric OS 6.3.0 Modify fipcfg --advintvl cli to reject non-zero values for FKA interval. Fixed in Fabric OS 6.3.0 CUP needs to send an RSCN after coming back online after a cold boot. Fixed in Fabric OS 6.3.0 WT: FCoE connected devices tab, sort order of Device WWN is incor- Fixed in Fabric OS 6.3.0 rect. In an FCR environment, switch runs out of memory when connected with EoS switches. Fixed in Fabric OS 6.3.0 Blades are not shown in when a slot is hot plugged in to a DC SAN Fixed in Fabric OS 6.3.0 Director or DC04 SAN Director. With VF, deleting a FID while in the FID leads to undesirable conditions. The user is stuck in the FID and all commands run generate an error Fixed in Fabric OS 6.3.0 message. Fabric OS still reports some FRU failures as link incidents on port 0xFF. Fixed in Fabric OS 6.3.0 After FCoE login, Fabric OS 6.1.2_cee does not filter packets with SRC-MAC=FCF-MAC. Fixed in Fabric OS 6.3.0 Reboot of all 4 nodes in an Encryption Group (EG) with multiple rekeys Fixed in Fabric OS 6.3.0 pending resulted in new rekey sessions being unable to start. IPFC address is shown instead of chasis IP address in SNMP Trap for Fixed in Fabric OS 6.3.0 DC04 SAN Director. Required detailed error description while the port enable/disable fails. Fixed in Fabric OS 6.3.0 Man page/online help on fcoelogingroup --create xxx should Fixed in Fabric OS 6.3.0 replace allow-all by "allowall." 54

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76

Fixed in Fabric OS 6.3.0
Workaround prior to code change:
Issue
switchdisable
and
switchenable
, which causes the
IPv6 Address again to be presented.
IPv6 Address dropped from
ag --show
.
Fixed in Fabric OS 6.3.0
Port statistics details are not getting refreshed for EX ports.
Fixed in Fabric OS 6.3.0
Workaround prior to code change:
Use CLI to map user defined priority
group to a CoS.
WebTools Switch Admin: QoS: User defined priority group 0-7 does
not show up in the drop down for priority group id.
Fixed in Fabric OS 6.3.0
8/8 or 8/16 returned invalid value for
swFCPortFlag
MIB object
from 8/8 or 8/16 on SNMP manager.
Fixed in Fabric OS 6.3.0
MAC learning/flushing times are very slow on 2408 FCoE CN Switch
Switch.
Fixed in Fabric OS 6.3.0
Switch crashed on sending LOGO from Finisar LT.
Fixed in Fabric OS 6.3.0
Virtual Fabrics 6.2.0c when XISL use is enabled base logical switch
in
switchshow
shows Allow XISL Use as "off" open RFE 1249.
Fixed in Fabric OS 6.3.0
Modify
fipcfg --advintvl
cli to reject non-zero values for FKA
interval.
Fixed in Fabric OS 6.3.0
CUP needs to send an RSCN after coming back online after a cold
boot.
Fixed in Fabric OS 6.3.0
WT: FCoE connected devices tab, sort order of Device WWN is incor-
rect.
Fixed in Fabric OS 6.3.0
In an FCR environment, switch runs out of memory when connected
with EoS switches.
Fixed in Fabric OS 6.3.0
Blades are not shown in when a slot is hot plugged in to a DC SAN
Director or DC04 SAN Director.
Fixed in Fabric OS 6.3.0
With VF, deleting a FID while in the FID leads to undesirable conditions.
The user is stuck in the FID and all commands run generate an error
message.
Fixed in Fabric OS 6.3.0
Fabric OS still reports some FRU failures as link incidents on port 0xFF.
Fixed in Fabric OS 6.3.0
After FCoE login, Fabric OS 6.1.2_cee does not filter packets with
SRC-MAC=FCF-MAC.
Fixed in Fabric OS 6.3.0
Reboot of all 4 nodes in an Encryption Group (EG) with multiple rekeys
pending resulted in new rekey sessions being unable to start.
Fixed in Fabric OS 6.3.0
IPFC address is shown instead of chasis IP address in SNMP Trap for
DC04 SAN Director.
Fixed in Fabric OS 6.3.0
Required detailed error description while the port enable/disable fails.
Fixed in Fabric OS 6.3.0
Man page/online help on
fcoelogingroup --create xxx
should
replace allow-all by "allowall."
54