HP StorageWorks 1606 HP StorageWorks Fabric OS 6.3.0c Release Notes (5697-0361 - Page 50
Transmitted Rate / Received rates based on the Bytes Transmitted
View all HP StorageWorks 1606 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 50 highlights
cp in slot 5 faulty. Fixed in Fabric OS 6.3.0 Mixing FibreChannel FastWrite (FCFW) and Non-FCFW flows can cause dcam entries to not be set correctly. Fixed in Fabric OS 6.3.0 I/O cannot resume when jamming the status frame with IDLE with QOS Fixed in Fabric OS 6.3.0 enabled. ZONEd panic and VERIFYs due to shmInit: shmget failed: No space left on device. Fixed in Fabric OS 6.3.0 Workaround prior to code change: Reboot the switch. In IM2, mixed fabric with over 500 devices, name server counts do not match for Fabric OS and EOSc switches in the same fabric. EOSn Fixed in Fabric OS 6.3.0 count matches Fabric OS name server count. FCIP VE port: Fast recovery does not handle pure out of order packets. Fixed in Fabric OS 6.3.0 Firmwarecommit failed on Active CP with "missing /etc/fabos/skm/IngrianNAE.properties" Fixed in Fabric OS 6.3.0 Workaround prior to code change: Execute the following commands on both Active and Standby CPs after the problem has occurred: cp /etc/ fabos/skm/ IngrianNAE.properties.template /etc/fabos/skm/ IngrianNAE.properties firmwarecommit Unable to launch WebTools on a DC SAN Director. Fixed in Fabric OS 6.3.0 File SW_v5_8.mib has internal notation that it is Version 5.7. Fixed in Fabric OS 6.3.0 CALD memory leak led to switch panic / fabric disruption. Fixed in Fabric OS 6.3.0 Detected termination of 0.weblinker.fcg:2045 (1) during deleting lo- Fixed in Fabric OS 6.3.0 gical switches. Data Miscompare after Encryption SAN Switch power cycle. Fixed in Fabric OS 6.3.0 Out of Memory due to switch not timing out in.telnetd processes. Fixed in Fabric OS 6.3.0 Workaround prior to code change: Reboot the switch. Transmitted Rate / Received rates based on the Bytes Transmitted / Bytes Received are greater than the peak rates (RateTxPeakByte & RateRxPeakByte). Fixed in Fabric OS 6.3.0 CP panic with FICUd crash occurred during supportsave operation. Fixed in Fabric OS 6.3.0 Workaround prior to code change: This can be avoided by doing one of the following after enabling FMSMODE for the first time: switchdisable/switchenable - hafailover - hareboot - reboot. 50