HP StorageWorks 8/80 Brocade Converged Enhanced Ethernet Administrator's Guide - Page 154

Configuring RMON events, Configuring RMON Ethernet group statistics collection

Page 154 highlights

13 RMON configuration and management 2. Configure the RMON alarms. Example of an alarm that tests every sample for a rising threshold switch(config)#rmon alarm 5 1.3.6.1.2.1.16.1.1.1.5.65535 interval 30 absolute rising-threshold 95 event 27 owner john_smith Example of an alarm that tests the delta between samples for a falling threshold switch(config)#rmon alarm 5 1.3.6.1.2.1.16.1.1.1.5.65535 interval 10 delta falling-threshold 65 event 42 owner john_smith 3. Enter the copy command to save the running-config file to the startup-config file. switch(config)#end switch#copy running-config startup-config Configuring RMON events You can add or remove an event in the RMON event table that is associated with an RMON alarm number. To configure RMON events, perform the following steps from Privileged EXEC mode. 1. Enter the configure terminal command to enter global configuration mode. switch#configure terminal 2. Configure the RMON event. switch(config)#rmon event 27 description Rising_Threshold log owner john_smith trap syslog 3. Enter the copy command to save the running-config file to the startup-config file. switch(config)#end switch#copy running-config startup-config Configuring RMON Ethernet group statistics collection You can collect RMON Ethernet group statistics on an interface. RMON alarms and events must be configured for you to display collection statistics. By default, RMON Ethernet group statistics are not enabled. To collect RMON Ethernet group statistics on an interface, perform the following steps from Privileged EXEC mode. 1. Enter the configure terminal command to enter global configuration mode. switch#configure terminal 2. Enter the interface command to specify the CEE interface type and slot/port number. Example of selecting the Ten Gigabit Ethernet port number 0/1. switch(config)#interface tengigabitethernet 0/1 3. Enable the CEE interface. switch(conf-if-te-0/1)#no shutdown 4. Configure RMON Ethernet group statistics on the interface. Example switch(conf-if-te-0/1)#rmon collection stats 200 owner john_smith 134 Converged Enhanced Ethernet Administrator's Guide 53-1001346-01

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162

134
Converged Enhanced Ethernet Administrator’s Guide
53-1001346-01
RMON configuration and management
13
2.
Configure the RMON alarms.
Example of an alarm that tests every sample for a rising threshold
switch(config)#
rmon alarm 5
1.3.6.1.2.1.16.1.1.1.5.65535
interval 30
absolute
rising-threshold 95 event 27 owner john_smith
Example of an alarm that tests the delta between samples for a falling threshold
switch(config)#
rmon alarm 5
1.3.6.1.2.1.16.1.1.1.5.65535
interval 10 delta
falling-threshold 65 event 42 owner john_smith
3.
Enter the copy command to save the running-config file to the startup-config file.
switch(config)#end
switch#
copy running-config startup-config
Configuring RMON events
You can add or remove an event in the RMON event table that is associated with an RMON alarm
number.
To configure RMON events, perform the following steps from Privileged EXEC mode.
1.
Enter the
configure terminal
command to enter global configuration mode.
switch#
configure terminal
2.
Configure the RMON event.
switch(config)#
rmon event 27 description Rising_Threshold log owner john_smith
trap syslog
3.
Enter the copy command to save the running-config file to the startup-config file.
switch(config)#end
switch#
copy running-config startup-config
Configuring RMON Ethernet group statistics collection
You can collect RMON Ethernet group statistics on an interface. RMON alarms and events must be
configured for you to display collection statistics. By default, RMON Ethernet group statistics are
not enabled.
To collect RMON Ethernet group statistics on an interface, perform the following steps from
Privileged EXEC mode.
1.
Enter the
configure terminal
command to enter global configuration mode.
switch#
configure terminal
2.
Enter the
interface
command to specify the CEE interface type and slot/port number.
Example of selecting the Ten Gigabit Ethernet port number 0/1.
switch(config)#
interface tengigabitethernet 0/1
3.
Enable the CEE interface.
switch(conf-if-te-0/1)#
no shutdown
4.
Configure RMON Ethernet group statistics on the interface.
Example
switch(conf-if-te-0/1)#
rmon collection stats
200
owner