Icom IC-R6 Instruction Manual - Page 49

Storing the skip frequencies during a VFO scan

Page 49 highlights

D Storing the skip frequencies during a VFO scan During a VFO scan, the skip frequencies can be stored into the highest blank memory channel which is automatically selected with the following operation. q Start a VFO scan. ➥ Push [V/M] to select the VFO mode. ➥ Set the squelch level. ➥ Hold down [SCAN](MODE) for 1 second to enter the scan type selection mode. ➥ Rotate [DIAL] to select a desired scanning type. • Select "ALL" for full scan, "BAND" for band scan, "P-LINK x" for programmed link scan (x= 0 to 9), "PROGxx" for programmed scan (xx= 0 to 24; only programmed scan edge numbers are displayed). ➥ Push [SCAN](MODE) to start the scan. w W hen the scan pauses and you want to set the paused frequency as a skip frequency. ➥ H old down [FUNC], then push and hold [S.MW](V/M) for 1 second to store the paused frequency into the highest blank memory channel. • While holding down [FUNC], the scan pauses; and after writing the frequency, the scan resumes. SCAN OPERATION 6 6 36

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96

36
6
SCAN OPERATION
6
D
Storing the skip frequencies during a VFO scan
During a VFO scan, the skip frequencies can be stored into
the highest blank memory channel which is automatically
selected with the following operation.
q
Start a VFO scan.
Push
[V/M]
to select the VFO mode.
Set the squelch level.
Hold down
[SCAN]
(MODE) for 1 second to enter the
scan type selection mode.
Rotate
[DIAL]
to select a desired scanning type.
• Select “ALL” for full scan, “BAND” for band scan, “P-LINK
x” for programmed link scan (x= 0 to 9), “PROGxx” for pro-
grammed scan (xx= 0 to 24; only programmed scan edge
numbers are displayed).
Push
[SCAN]
(MODE) to start the scan.
w
When the scan pauses and you want to set the paused
frequency as a skip frequency.
Hold down
[FUNC]
, then push and hold
[S.MW]
(V/M)
for 1 second to store the paused frequency into the
highest blank memory channel.
• While holding down
[FUNC
], the scan pauses; and after
writing the frequency, the scan resumes.