Icom IC-R6 Instruction Manual - Page 62
Expand set mode EXPAND, Key lock effect LOCK, Dial speed acceleration SPEED, Monitor switch action
View all Icom IC-R6 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 62 highlights
9 SET MODE D Expand set mode (EXPAND) Turn the Expand set mode ON or OFF. (default: OFF) • OFF : Displays only the regular Set mode. • ON : Displays the regular set mode and the Expand set mode. D Dial speed acceleration (SPEED) The dial speed acceleration automatically speeds up the tuning dial speed, when rotating [DIAL] rapidly. (default: ON) • OFF : The dial speed acceleration is turned OFF. • ON : The dial speed acceleration is tuned ON. D Key lock effect (LOCK) Even while the key lock function is ON, the volume control, squelch adjustment and monitor key ([SQL]) is still usable. Usable keys can be set to one of four groups. [ ] and [FUNC]+[ ](BAND) are also usable during the locked state. However, these switches are not effected by this setting. (default: NORMAL) • NORMAL : Volume control, squelch adjustment and monitor key are accessible. • NO SQL : The squelch adjustment and monitor key are accessible. (The function of [SQL] is not locked.)* • NO VOL : Volume control is accessible. (The function of volume control is not locked.)* • ALL : No key function is usable, except [ ] and [FUNC]+[ ](BAND). *"NO" indicates the function is not locked. D Monitor switch action (MONI) The monitor switch, [SQL], can be set as a 'sticky' switch. When set to the sticky condition, each push of [SQL] toggles the monitor function ON or OFF. (default: PUSH) • PUSH : Hold down [SQL] to monitor the frequency. • HOLD : P ush [SQL] momentarily to monitor the fre- quency and push momentarily again to cancel it. 49