Intel X5365 Design Guide - Page 56
A.2 Thermal Solution Performance Characteristics, A-2
UPC - 735858199292
View all Intel X5365 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 56 highlights
1U Alternative Heatsink Thermal/Mechanical Design A.2 Thermal Solution Performance Characteristics Figure A-2 shows the performance of the 1U alternative heatsink. This figure shows the thermal performance and the pressure drop through fins of the heatsink versus the airflow provided. The best-fit equations for these curves are also provided to make it easier for users to determine the desired value without any error associated with reading the graph. Figure A-2. 1U Alternative Heatsink Thermal Performance Table A-1. 1U Alternative Heatsink Thermal Mechanical Characteristics Size Height Weight Target Airflow Through Fins Mean Ψca Standard Deviation Ψca (mm) [in.] (kg) [lbs] (m3/hr) [CFM] 1U 27.00 0.24 [0.53] 25.5 [15] [1.06] (°C/W) 0.304 (°C/W) 0.007 Pressure Drop (Pa) [in H2O] 82.4 [0.331] 56 Quad-Core Intel® Xeon® Processor 5300 Series Thermal/Mechanical Design Guidelines (TMDG)