Intel X5365 Design Guide - Page 56

A.2 Thermal Solution Performance Characteristics, A-2

Page 56 highlights

1U Alternative Heatsink Thermal/Mechanical Design A.2 Thermal Solution Performance Characteristics Figure A-2 shows the performance of the 1U alternative heatsink. This figure shows the thermal performance and the pressure drop through fins of the heatsink versus the airflow provided. The best-fit equations for these curves are also provided to make it easier for users to determine the desired value without any error associated with reading the graph. Figure A-2. 1U Alternative Heatsink Thermal Performance Table A-1. 1U Alternative Heatsink Thermal Mechanical Characteristics Size Height Weight Target Airflow Through Fins Mean Ψca Standard Deviation Ψca (mm) [in.] (kg) [lbs] (m3/hr) [CFM] 1U 27.00 0.24 [0.53] 25.5 [15] [1.06] (°C/W) 0.304 (°C/W) 0.007 Pressure Drop (Pa) [in H2O] 82.4 [0.331] 56 Quad-Core Intel® Xeon® Processor 5300 Series Thermal/Mechanical Design Guidelines (TMDG)

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100

1U Alternative Heatsink Thermal/Mechanical Design
56
Quad-Core Intel® Xeon® Processor 5300 Series Thermal/Mechanical Design Guidelines (TMDG)
A.2
Thermal Solution Performance Characteristics
Figure A-2
shows the performance of the 1U alternative heatsink. This figure shows the
thermal performance and the pressure drop through fins of the heatsink versus the
airflow provided. The best-fit equations for these curves are also provided to make it
easier for users to determine the desired value without any error associated with
reading the graph.
Figure A-2.
1U Alternative Heatsink Thermal Performance
Table A-1.
1U Alternative Heatsink Thermal Mechanical Characteristics
Size
Height
Weight
Target Airflow
Through Fins
Mean
Ψ
ca
Standard
Deviation
Ψ
ca
Pressure
Drop
(mm) [in.]
(kg) [lbs]
(m
3
/hr) [CFM]
(
°
C/W)
(
°
C/W)
(Pa) [in
H
2
O]
1U
27.00
[1.06]
0.24 [0.53]
25.5 [15]
0.304
0.007
82.4 [0.331]