Linksys SPA921 Cisco SPA9000 Voice System Administration Guide - Page 113
Configuring a SPA400 for PSTN Access, Status, Voice tab > Info, Save Settings
UPC - 745883570799
View all Linksys SPA921 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 113 highlights
Administering the SPA400 and Voice Mail Service Configuring a SPA400 for PSTN Access 5 line. The call is directed according to the Contact List. Also, in the SPA400 web configuration page, click the Status tab, and then verify that a voltage value appears in the Battery Level section. SPA400 Administration > Status: Battery Level NOTE If the battery level is 0 V on a line that you have connected to the PSTN, troubleshoot the phone wiring. • Connect to the SPA9000 administration web server, and choose Admin access with Advanced settings. Click Voice tab > Info. Scroll down to the Line 2 Status section, and verify that the Registration Status is Registered. STEP 12 Click Save Settings. NOTE If you are using this SPA400 for voice mail service, continue to "Configuring a SPA400 for Voice Mail Service," on page112. Configuring a SPA400 for PSTN Access Typically, there is no need to change the default settings on the Voice page. Make changes only if a problem is suspected and only after consulting with a service technician from your telephone service provider. It is essential that the settings on your system are compatible with those of the Central Office. SPA9000 Voice System Administration Guide 111