Ricoh Aficio MP C3500 Network Guide - Page 67
Remote Maintenance by telnet, Using telnet
View all Ricoh Aficio MP C3500 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 67 highlights
Remote Maintenance by telnet Remote Maintenance by telnet Important C Enter a command. ❒ Remote Maintenance should be password-protected so that access D Quit telnet. is allowed to administrators only. ❒ The password is the same as the msh> logout The configuration message about 2 one of Web Image Monitor admin- saving the changes appears. istrator. When the password is changed using "mshell", other passwords change also. E Enter "yes" to save the changes, and then press the {Enter} key. ❒ Some command cannot be set depending on the model type. If you do not want to save the changes, enter "no", and then press the {Enter} key. To make further Using telnet changes, enter "return" at the command line, and then press the {En- Follow the procedure below to use telnet. Important ❒ Only one user at a time can log on to perform remote maintenance. ter} key. Note ❒ If the message "Can not write NVRAM information" appears, the changes are not saved. Repeat the procedure above. A Use the IP address or the host name of the machine to start telnet. % telnet IP_address B Enter your user name and pass- word. For details about the user name and password, consult your network administrator. ❒ When the changes are saved, the network interface board is reset automatically with that changes. ❒ When the network interface board resets, the print job in print process will be printed. However, print jobs in queue will be canceled. For user authentication, enter a login user name and password. For user code authentication, enter a user code in User Name. 59