Sanyo VDC-HD3300 VDC-HD3300 Manual - Page 86
Working with Administrator Configuration Screens 38/50
UPC - 086483075087
View all Sanyo VDC-HD3300 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 86 highlights
1 In [ALARM OUT1], select "REMOTE". Selecting "REMOTE" does not cause the terminal to output an alarm signal automatically even if an alarm condition is detected. 2 In [POLARITY], select the signal polarity of the alarm output terminal. NO (Normally Open): The terminal is normally open and closes when an alarm signal is output. NC (Normally Closed): The terminal is normally closed and opens when an alarm signal is output. 3 In [ALARM OUT TIME], select how long you want the terminal to output the alarm signal and click SET . The terminal will stop outputting the alarm signal when the set alarm output time expires. 2SEC, 5SEC, 10SEC, 15SEC, 30SEC, 45SEC, 1MIN, 2MIN, 3MIN, 4MIN, 5MIN CC (Stops outputting the alarm signal when the corresponding Remote Alarm button is clicked on the live screen.) To configure the ALARM OUT 2 terminal to output an alarm signal when a Remote Alarm button is clicked, select "REMOTE" in [ALARM OUT2] and specify the output conditions for it in the same way as for the ALARM OUT1 terminal. Working with Administrator Configuration Screens 38/50