Sharp PN-T322B Service Manual - Page 37
Serial Number Writing Procedures, Start-up Of The Serial Num
View all Sharp PN-T322B manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 37 highlights
CHAPTER 5. SERVICE MENU/VARIOUS SETTING TOOL OPERATING PROCEDURES 7. SERIAL NUMBER WRITING PROCEDURES 7 - 1. OPERATING CONDITIONS OF THE SERIAL NUMBER SETTING TOOL The operating conditions of the serial number setting tool of the information display are as follows. OS Communication port n Windows XP n Windows Vista n Windows 7 n RS-232C port recognized as a COM port (Which can be communicate in 9600bps.) ■ WHEN CONNECTED TO THE INFORMATION DISPLAY WITH AN RS-232C CABLE The required RS-232C cable is as shown below. Connect the PC's COM port and the RS-232C input terminal of the display with the cable. 7 - 2. START-UP OF THE SERIAL NUMBER SETTING TOOL Press [Serial Number] button of the Service Tool Launcher. 7 - 3. SERIAL NUMBER SETTING PROCEDURES RS-232C cable Straight cable (D-SUB 9pin female - female) The procedures of setting serial numbers with use of the Serial Number Setting Tool are as follows. 1 ) Press [Connection Setting...] button to configure the communication settings. 2 ) Input the serial number you need to set in the field of Write Data. 3 ) Press [Write] button. 4 ) Press [Read] button, and confirm that the set serial number is dis- played in the Read Data field. 7 - 4. SERIAL NUMBER CHECK METHOD Press [Display] button on the remote controller to indicate the display information, and check the serial number. PN-T321/T322B SERVICE MENU/VARIOUS SETTING TOOL OPERATING PROCEDURES 5 - 4