Sharp PN-T322B Service Manual - Page 40
Reset Of The Temperature, Watch Settings
View all Sharp PN-T322B manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 40 highlights
CHAPTER 5. SERVICE MENU/VARIOUS SETTING TOOL OPERATING PROCEDURES 9 - 4. RESET OF THE TEMPERATURE WATCH SETTINGS In the cases below, reset the settings by following the procedures. n When the previous temperature watch settings remain at the time of replacing the PWB. n When the usage time has been reset at the time of replacing the panel or the like. MEMO n The temperature watch setting data contains a part that stores the usage time of the display as basic information. 1 ) Press [Reset] button to execute the reset. 2 ) To confirm that the settings have been properly reset, press [Read] button to read out the set values. 3 ) For the default settings, please see the followings. DEFAULT THRESHOLD TEMPERATURE PN-T321 Installation Orientation Brightness down temperature (Level 5 of brightness) Shutdown temperature Landscape installation 58 Portrait installation 57 62 62 PN-T322B Installation Orientation Brightness down temperature (Level 5 of brightness) Shutdown temperature Landscape installation 58 Portrait installation 58 62 62 PN-T321/T322B SERVICE MENU/VARIOUS SETTING TOOL OPERATING PROCEDURES 5 - 7