3Com 3C780 User Guide - Page 61

Pin No., Function

Page 61 highlights

Installing the Hub 2-21 Table 2-1. DB-9 STP Connector Pin Assignments Pin No. 1 2 3 4 5 6 7 8 9 Function Transmit (+) Not used Not used Not used Receive (+) Transmit (-) Not used Not used Receive (-) Unshielded Twisted-Pair Cable s The standard UTP cabling type supported by the LinkBuilder FDDI Workgroup Hub is category 5 screened UTP cross-over cable with screened RJ-45 connectors, as specified by ANSI X3T9.5. The cross-over cable connections and color scheme are shown in Figure 2-7. s The maximum length of this cable from the hub to any potential end station is 100 m (328 ft). The cross-over cable connects the LinkBuilder FDDI hub and the punchdown block. ANSI standards specify the operating distances, as shown in Figure 2-8. s The pin assignments for the type RJ-45 FDDI unshielded twisted-pair interface connector are shown in Table 2-2. Brown 1 Green 2 Blue 3 Orange 4 5 Orange 6 Blue 7 Green 8 Brown Figure 2-7. Cross-over Connections on a UTP Cable

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169
  • 170
  • 171
  • 172
  • 173
  • 174
  • 175
  • 176

2-21
Installing the Hub
Table 2-1.
DB-9 STP Connector Pin Assignments
Pin No.
Function
1
Transmit (+)
2
Not used
3
Not used
4
Not used
5
Receive (+)
6
Transmit (–)
7
Not used
8
Not used
9
Receive (–)
Unshielded Twisted-Pair Cable
The standard UTP cabling type supported by the LinkBuilder FDDI
Workgroup Hub is category 5 screened UTP cross-over cable with
screened RJ-45 connectors, as specified by ANSI X3T9.5.
The cross-over
cable connections and color scheme are shown in Figure 2-7.
The maximum length of this cable from the hub to any potential end station
is 100 m (328 ft).
The cross-over cable connects the LinkBuilder FDDI
hub and the punchdown block.
ANSI standards specify the operating
distances, as shown in Figure 2-8.
The pin assignments for the type RJ-45 FDDI unshielded twisted-pair
interface connector are shown in Table 2-2.
5
1
6
2
7
3
8
4
Brown
Green
Blue
Orange
Brown
Green
Orange
Blue
Figure 2-7.
Cross-over Connections on a UTP Cable